Eastwood Elite QST-30 Instructions Manual

Eastwood Elite QST-30 Instructions Manual

Scroll compressor
Hide thumbs Also See for Elite QST-30:

Advertisement

Quick Links

Item #63600
QST-30/60
®
SCROLL COMPRESSOR
INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Eastwood Elite QST-30

  • Page 1 Item #63600 QST-30/60 ® SCROLL COMPRESSOR INSTRUCTIONS...
  • Page 2: Specifications

    The unique Scroll pump design also has far fewer moving parts and significantly reduced friction for greater reliability and longer life. CONTENTS (1) Eastwood Elite QST 30/60 Scroll Type Air Compressor MOISTURE CATCH SYSTEM HARDWARE (1) 500ml clear, oil and moisture resistant Bottle (1) Lid Assembly (includes: Metal Outer Lid, Lid Liner, Gasket, Hardware) (1) 90°...
  • Page 3: Safety Information

    • Air, moisture and debris can be ejected at high velocity while using this equipment. Always wear ANSI Z87 approved eye protection when operating this compressor and associated equipment. HEALTH HAZARD! • Air discharged from this compressor is not intended for and should never be used as supply air for human consumption. To order parts and supplies: 800.343.9353 >> eastwood.com...
  • Page 4 • To provide proper ventilation for cooling and prevent overheating, the compressor must be kept a minimum of 12 inches (31 cm) from the nearest wall, in a well–ventilated area. • The Eastwood Elite QST 30/60 Compressor is mounted on Casters and can vibrate or move slightly during operation. Always lock Casters before running.
  • Page 5: Step 1 - Check Oil Level

    FIG. 4 FIG. 4 • If needed, add #31718 Eastwood Synthetic Scroll Compressor Oil to the fill port of the Oil Reservoir using a suitable funnel (FIG 5). • Check the condition of the Seal then replace Oil Fill Plug/Dipstick and tighten securely.
  • Page 6: Step 2 - Check Air Filter

    Compressor is disconnected. When the FIG. 8 FIG. 8 switch is on, the compressor will start and stop automatically as it will be controlled by the pressure switch. Eastwood Technical Assistance: 800.343.9353 >> tech@eastwood.com...
  • Page 7 If any air or oil leaks are discovered, call Eastwood Tech at: 1-800-343-9353 or email at tech@eastwood.com • If no leaks exist, the Eastwood Elite QST 30/60 Compressor is now ready for use. FIG. 12 FIG.
  • Page 8: Compressor Location

    AIR LINE CONNECTION The Eastwood Elite QST 30/60 Compressor is designed with a high efficiency, 1/2” Ball Valve at the air outlet with 1/2” FNPT threads. It is strongly recommended to use 1/2” or larger air lines and fittings throughout your system. The use of 3/8” or smaller lines is acceptable but will greatly hamper performance.
  • Page 9 • Close Drain Valve securely when finished. Condensate is a polluting material and should be disposed of in compliance with local regulations. If drain valve becomes clogged, release all air pressure, remove and clean valve, then reinstall. To order parts and supplies: 800.343.9353 >> eastwood.com...
  • Page 10: Maintenance

    NOTE: Do not lose the Oil Fill Plug/Dipstick seal. • Add #31718 Eastwood Synthetic Scroll Compressor Oil to the fill port of the Oil Reservoir using a suitable funnel (FIG 5). • With the Compressor sitting on a level surface, check oil level by observing the level on the Dipstick. The oil level is acceptable when it is between the marks (FIG 3).
  • Page 11: Oil And Filter Change

    NOTE: Do not lose the Oil Fill Plug/Dipstick seal. • Add #31718 Eastwood Synthetic Scroll Compressor Oil to the fill port of the Oil Reservoir using a suitable funnel (FIG 5). • With the Compressor sitting on a level surface, check oil level by observing the level on the Dipstick. The oil level is acceptable when it is between the marks (FIG 3).
  • Page 12: Air Filter Change

    • Remove the Air Filter Element and discard it. • Replace the Air Filter Element with a new Eastwood #31717 and re-install the Air Filter Housing Lid. Note that the peg of the Air Cleaner Cover must be indexed with one of the 5 recesses around the circumference of the Filter Housing and the snorkel of the Air Cleaner Housing must be pointing downward (FIG 8).
  • Page 13: Troubleshooting

    Intake Check valve. The valve It will not harm or hinder performance of unit and will cease after a few cycles. When Unit seal is making the noise. Starts To order parts and supplies: 800.343.9353 >> eastwood.com...
  • Page 14 Shuts Off Early Replace Pressure Switch #32207. (On/Off switch). Light, intermittent use, operation Drain and replace oil with 2 qts #31718 Eastwood Scroll Compressor Oil. Sludge in Oil in warm, damp locations, or during Replace Oil Filter #31715. Tank and On high humidity weather conditions will Replace Moisture Filter #31716.
  • Page 15 NOTES To order parts and supplies: 800.343.9353 >> eastwood.com...
  • Page 16: Additional Items

    Replacement 24” Nylon Hose Kit If you have any questions about the use of this product, please contact The Eastwood Technical Assistance Service Department: 800.343.9353 >> email: tech@eastwood.com PDF version of this manual is available at eastwood.com The Eastwood Company 263 Shoemaker Road, Pottstown, PA 19464, USA 800.343.9353 eastwood.com...