Command 6 - System Setup; Command 8 - Sampling Start; Command 10 - Sensor Warmup; Command 12 - Data Send Sequence - Casio EA-200 User Manual

Casio calculator user's guide ea-200
Hide thumbs Also See for EA-200:
Table of Contents

Advertisement

Command 6 - System Setup

{ 6, Command, Auto Power Off Time }
Command
0 or 2
Abort Sampling
( *0)
3
Turns sound off
4
Turns sound on
10
APO
(Auto Power Off)

Command 8 - Sampling Start

{ 8 }
Command 11 -
Buzzer and LED Operation Commands
{ 11, Output Select, Length, Period }
Output Select
* 0
Buzzer
2
Ready LED
3
Sampling LED
4
Error LED
5
Batt LED
• An error occurs when fraction data is sent.
• Send commands to the EA-200 in accordance with the command table contents.
• An error occurs when a parameter that does not exist in the command table is sent.
• The EA-200 uses six digits for internal calculations.
APO Time(sec)
–––
* 0
1800
1
10
2
360
Length (sec)
Period (sec)
Operating Time (sec)
Period (sec)
-1-4
English

Command 10 - Sensor Warmup

{ 10, Warmup Time (sec) }
Warmup Time (sec)
0.1 to 360

Command 12 - Data Send Sequence

{ 12, Send Sequence }
Send Sequence
–––
20020601
Warmup time (sec)
( *0.1)
0
Auto
–1
None
–2
Normal warmup
* 0
Non-real Time Format
1
Real Time Format

Advertisement

Table of Contents
loading

Table of Contents