TROUBLESHOOTING

During installation, test the fiber and twisted pair connections with all
troubleshooting features disabled. Once the physical connections have
been established, the troubleshooting features of LinkLoss and FiberAlert
can be enabled by using the DIP Switches or configuring them using the
iView² software. However, it is important to remember that software will
override hardware settings.
Although a specific link segment, either the copper or the fiber, can be
established, if the LNK LEDS do not reflect a state of active power, it is
best to connect both segments.
If an SM fiber transceiver is deployed for a short distance application,
saturation may occur, contributing to loss of data or link. In such a case,
add an optical attenuator to the fiber connection.

SPECIFICATIONS

Operating Temperature
0 to +50 °C (+32 to +122 °F)
Storage Temperature
-25 to +70 °C (-13 to +158 °F)
Humidity
5 to 95% (non-condensing)
Power Consumption (typical)
Input Load: 500 mA
iMcV-Giga-MediaLinX