13.11. Adjust camera scales and positions
Adjust the camera scale and position of the mask camera, PCB camera and inspection camera. For
information about reference marks used for the adjustment, see "13.3
adjustment".
13.11.1. Adjust the mask camera's scale
In the procedure described in this section, use the glass QFP.
Tool appearance and
features
Glass QFP with 208pins
Use this QFP with a white seal on the entire back to be recognized its 4 0.5mm holes on the corners.
In the CalibSm Main Menu, press the [203 Camera] button.
Select "Mask Camera".
Part number
・KM0-M880A-20
・KM0-M880A-10
SI1906002E-001=YSP10 installation and adjustment procedures
90/120
For Service Engineers
Service Information
Reference marks used for
Remark
Select "Mask Camera".