REPLACING THE GASKET

Door gaskets should be checked and cleaned regularly and replaced if damaged. To clean the gasket, wipe with warm
soapy water and a soft cloth, ensuring it is completely dry before closing the door. DO NOT use a sharp knife to clean
or scrape the gasket. Damaged gaskets do not seal correctly and can increase the amount of electricity consumed,
seriously affecting the efficiency and performance of the cabinet. Damaged gaskets are easily replaced. Simply pull
out existing part and push new gasket into channel (gasket retainer) at centre and work along, pushing gasket into
channel. Continue with additional three sides, pushing corners in last.
BREAKDOWN
In the event of a breakdown, please check thermostat setting and fuse before calling service engineer. When
calling, please advise model and serial number. This information can be found on identification plate inside cabinet.
It should also be noted on the cover of this booklet. Please ensure that all redundant parts are disposed of safely
and legally.