Ethernet modules
Hard disk drive modules
The front panel of the appliance includes four, 2.5 inch hard disk drive modules.
The appliance supports SAS hard disk drives, and there are two LEDs on each
hard disk drive module. The left LED monitors hard disk activity, and the right
LED indicates a potential problem:
v A green flashing LED indicates that the hard disk drive is being accessed.
v An amber flashing LED indicates that the hard disk drive has failed.
v No LED illuminated indicates the hard disk drive is not active.
Note: The hard disk drive modules are not hot-swappable. Hot swapping the

Type 7199-92x rear view

The rear view shows the components and LEDs on the rear of the appliance. The
fan modules and power modules are installed from the rear of the appliance.
6
WebSphere DataPower XC10 Appliance: Type 7199-92X: Installation and User's Guide
v The green LED indicates the port is linked.
v The green flashing LED indicates the port is active.
The DataPower appliance has two Ethernet modules for Ethernet
connectivity. The left Ethernet module has eight RJ45 ports, and the right
Ethernet module has two 10 Gb small-form factor pluggable (SFP+) ports.
The name of the Ethernet interface depends on the module configuration,
with the Ethernet interface names dependent on the Ethernet module
configuration.
The 1 gigabit module supports Ethernet with unshielded, twisted-pair with
interface standards and includes:
v 10BASE-T
v 100BASE-TX
v 1000BASE-T
The 10 Gigabit module supports SFP+ ports with interface modules and
patch cables that always includes auto-negotiation:
10GBASE-SR
10GBASE-LR
Left Ethernet module
Has eight unshielded, twisted-pair (RJ45) Ethernet ports. The
Ethernet numbers range from ETH0 to ETH7 and correlate to the
number of available ports.
Right Ethernet module
Has two 10 Gigabit small form-factor pluggable (SFP+ ports. The
Ethernet numbers range from ETH8 to ETH9 and correlate to the
number of available ports.
See "Ethernet network configuration" on page 8 for a description of
Ethernet numbering.
Note: The Ethernet modules are not hot-swappable. Hot swapping the
modules causes your system to crash, and could possibly damage
your appliance.
modules could cause your system to crash.