INTRODUCTION Thank you for purchasing this Goodway conveyor cleaner. We appreciate your business and look forward to serving you in the future. As with all Goodway products, you can be assured that the finest quality components and workmanship have gone into this machine.
• Check the steam hose and all accessories for damage before use and replace or have them repaired immediately. • In the event of leakage of steam or liquid, turn off the Goodway steam cleaning unit and contact the manufacturer or service center.
• Always check the set-up before operation and after moving the machine. • Make sure the conveyor is stationary before setting-up the machine. FOR DETAILS ABOUT THE GOODWAY STEAM CLEANING UNIT, REFER TO THE INSTRUCION MANUAL SUPPLIED WITH THE GOODWAY STEAM CLEANER.
To test function and alignment, it will be necessary to put the cleaning head in place and clamp into the operating position. Clamping and releasing will align the head by having it in operating position and then settle in a rest position (see page 11 for details). 93-ACC-BRUSHLESS 11/14/2016...
Page 9
Locate side guide pegs into the guide rails. As the pins push forward, the guide rails will lift slightly. The lip is there to prevent the guide pegs from dropping out of the guide rails. Carefully slide the head fully into place, ensuring all four pins are engaged 93-ACC-BRUSHLESS 11/14/2016...
Page 10
Check the following before operating: • The cleaning heads are locked in their operational position • The Goodway steam cleaning unit is prepared, up to temperature, and connected to the water supply • The interlock plug is engaged •...
Page 11
When the unit is going to be operational, engage the toggle clamps on both ends as show below. When the unit is not going to be in use, it should be put in the rest position. This involves disengaging the toggle clamps on both ends as shown below. 93-ACC-BRUSHLESS 11/14/2016...
BRUSHLESS system. What to Expect: At first start up there will be an initial purge of water from the Goodway steam cleaning unit, plus condensate caused by steam cooling on components, especially the metal covers. Some of this will find its way into the drip tray. During use some drips will collect in the drip tray.
Page 13
However this may need to be adjusted more. A deflection on the belt approximating the side view is about right for optimum effect. If this is not drying the belt to an acceptable amount a more powerful vacuum may be required. 93-ACC-BRUSHLESS 11/14/2016...
Cleaning is inadequate Not enough steam Increase the volume of steam produced by the steam cleaning unit. Steam is too dry/wet Adjust the moisture level on the steam cleaning unit. 93-ACC-BRUSHLESS 11/14/2016...
Page 21
We Are Here to Serve You! For Sales Call: 1-800-333-7467 For Service Call: 1-800-370-2855 Goodway Technologies Corporation manufactures and distributes a complete line of Tube/Pipe Cleaning Systems, Duct Cleaning Systems, Vacuums, Floor Machines, Hi-Pressure Washers and other maintenance related equipment.
Need help?
Do you have a question about the 93-ACC-BRUSHLESS and is the answer not in the manual?
Questions and answers