Certification
6.2 EMC and Environmental Type Tests
61000-4-29
61000-4-11
61000-4-12
61000-4-16
61000-4-17
IEC 60255-5
IEEE 1613 (C37.90.x) EMC Immunity Type Tests
Note
RUGGEDCOM products meet Class 1 requirements for copper Ethernet
configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
IEEE Test
C37.90.3
C37.90.2
C37.90.1
30
Test
IEC
Voltage Dips and Interrupts
IEC
IEC
Damped Oscillatory
IEC
Mains Frequency Voltage
IEC
Ripple on DC Power Supply
Dielectric Strength
HV Impulse
IEEE 1613
Clause
9
8
7
Description
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
DC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Description
ESD
Enclosure Contact
Enclosure Air
Radiated RFI
Enclosure ports
Fast
Signal ports
Transient
DC Power ports
Test Levels
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
30% for 1 period,
60% for 50 periods
100% for 5 periods,
100% for 50 periods
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
30 V Continuous,
300 V for 1 s
30 V Continuous,
300 V for 1 s
10%
2 kVAC  (Fail-
Safe Relay output)
1.5 kVDC
2 kVDC
5 kV  (Fail-Safe
Relay Output)
5 kV
5 kV
Test Levels
±8 kV
±15 kV
35 V/m
±4 kV @ 2.5 kHz
±4 kV
Installation Manual, 12/2021, C79000-G8976-1021-06
Severity
Levels
 
 
 
3
3
3
4
4
3
 
 
 
 
 
 
RUGGEDCOM RS8000A