Rev.4 del 01/2011 O.M.A.C. s.r.l.
Before carrying out any intervention on the LDPU, read and understand this chapter in full. The operators responsible for the assembly/installation acti-
vities must have good familiarity with this type of equipment and possess recognised technical skills acquired in at least three years of similar activities,
this experience is essential to limit and reduce the risks involved in assembly/installation activities.
Good knowledge of the systems and components of the LDPU is essential before carrying out any operation.
DANGER
Assembly and disassembly operations of the LDPU, performed incorrectly and / or differently from the instructions herein, could be extremely dangerous
and cause injuries.
Only use the tools and utensils listed in this manual; furthermore during assembly and disassembly operations one must wear personal protection equi-
pment, listed in section 1.9 of chapter 1.

3.1 Destination and intended environments

In order to ensure maintaining the hygienic levels required by the customer, one must install the LDPU in closed work environments, whose features
comply with the requirements of this manual; the fl oor must be level, made of concrete, without bumps and solid enough not to collapse.
In the event the LDPU is supplied for alimentary use, the work environment must meet specifi c hygiene regulations requirements.
ATTENTION
The "B series lobe displacement Pump Unit" must be installed in closed work environments, not exposed to weather.
ATTENTION
Installation of the LDPU for alimentary use and its place of use must comply with the hygienic and sanitary standards required by the legislation in
force.
In order to facilitate installation, use, sanitisation and maintenance of the LDPU, the Customer must prepare a space free from obstacles, with a free
2
area of at least 3m
.
ATTENTION
A work space below 3 m
2
may lead to incorrect installation of the LDPU as well as non-functional nor easy maintenance
3.2 Condizioni ambientali
The "B series lobe displacement Pump Unit" gives maximum performance when used in work environments that meet the following work conditions:
ATTENTION
IT IS FORBIDDEN TO USE THE LDPU IN ENVIRONMENTAL CONDITIONS OTHER THAN THOSE INDICATED ABOVE.
ATTENTION
ONE PROHIBITS ALIMENTARY USE OF THE LDPU IN ENVIRONMENTS THAT DO NOT MEET THE HYGIENIC AND SANITARY STANDARDS RE-
QUIRED BY THE LEGISLATION IN FORCE.

3.2.1 Room lighting

The Customer must ensure suitable lighting of the work area, as required by EU Directives and the work legislation in force.
So not to cause refl ections that can distract and dazzle workers or prevent, even partially, reading the control panels and signals, when provided by the
LDPU confi guration, we recommend using a diffused light.
NOTE
For maintenance and repairs interventions on the machine it is recommended to use a portable battery torch, which can be orientated in the most appro-
priate direction depending on the kind of intervention.

3.3 Installation and assembly

The assembly and installation of the LDPU must be performed only by qualifi ed personnel, authorised by the Customer in compliance with the standards
in force, as well as observing the instructions supplied below.
RELATIVE HUMIDITY BELOW 50%
ROOM TEMPERATURE BETWEEN +5°C AND +40°C
Via Giovanni Falcone, 8
42048 Rubiera (RE) - Italy
E-mail:info@omacpompe.com SitoWeb:www.omacpompe.com
CHAPTER 3: LDPU B SERIES INSTALLATION
O.M.A.C. s.r.l.
Tel.0522/629371 - 629923 Fax 0522/628980
1
Chap.3 - pag.