DANGER
During hoisting and transportation ensure that there are no exposed persons in a dangerous area.

2.2 Delivery and unpacking

a. Delivery
All the material supplied to the customer is accurately checked by O.M.A.C. s.r.l. before shipment. Upon receipt of the LDPU ensure that the material
has not been damaged during transport and that the package has not been tampered with resulting in removal of parts from the inside. If one fi nds the
package is damaged, immediately notify the carrier and O.M.A.C. s.r.l. producing photographic documentation.
WARNING
With reference to the table at the beginning of this chapter, the weight of the LDPU can vary according to its version and dimensions of the products it is
made up of. The units must be handled using hoisting equipment, complete with the relative accessories.
b. Unpacking
Take utmost care during the unpacking operations of the LDPU and complete the following steps:
Open the crate, using an electric screwdriver to remove the fi xing screws of the crate lid;
Carefully remove the packaging from the LDPU;
Check is the LDPU has any visible signs of damage;
Place the packaging in the warehouse;
Ensure that there are the protective plastic caps closing the connections openings;
Ensure that the equipment supplied with the LDPU is not damaged.
In the event there is damage or parts are missing, immediately notify the carrier and O.M.A.C. s.r.l. producing photographic documentation.
Unless otherwise indicated the LDPU is shipped fully assembled, protected by a nylon sheet and set in a wooden crate. Fixing is achieved with four wood
screws (see table in section 2.4); positioned in the appropriate pre-drilled holes on the LDPU support base. Should the user need to transport the LDPU
one must restore the conditions described above.
WARNING
Keep the LDPU packaging with care, during its entire operating period. The original packaging is needed for a possible transfer of the LDPU, after its
fi rst installation.

2.3 Conditions for storage or extended interruptions of service

The LDPU has been designed for immediate use, however if the machine down time conditions should occur for long periods, one must:
disconnect the LDPU from the electrical mains;
following the instructions in this UMM, disconnect the LDPU from the plant it is connected to; close the suction inlets and delivery outlets with
the supplied closure plugs.
with reference to chapter 5 remove the seals and see to cleaning and sanitising them;
lubricate and clean the seals, the pump body and the parts contained;
put the LDPU back in its original packaging, as instructed in section 2.4, covering the electric supply and control panels with particular care;
place the LDPU on scaffolding with suitable capacity to support the weight of the LDPU, avoiding putting weights on top of the machine;
store the LDPU in a dry place, in its original packaging, positioning it according to the instructions shown on the crate;
store it at a room temperature above +5°C and below +30°C, and keep it in a sheltered place away from weather or other.
WARNING
Place the LDPU back on the scaffolding with suitable capacity to support the weight of the LDPU.
WARNING
In order to keep the features of the LDPU unvaried, one must comply with all the instructions above and it is recommended to avoid particularly damp
environments.
2
Chap.2 - pag.
Via Giovanni Falcone, 8
42048 Rubiera (RE) - Italy
E-mail:info@omacpompe.com SitoWeb:www.omacpompe.com
O.M.A.C. s.r.l.
Tel.0522/629371 - 629923 Fax 0522/628980
Rev.4 del 01/2011 O.M.A.C. s.r.l.