2.7 D OCUMENT CREATION This document was created using the “Avisaro Document Builder”. Single text blocks are merged into targeted documents. Thus, text blocks can be reused in several places, yet no need to update them manually when changes occur.
Jump to: Table of Content 2.8 I MPRINT AND CONTACT This document is provided by: Avisaro AG Grosser Kolonnenweg 18 E 30163 Hannover Germany Web: www.avisaro.com Email: info@avisaro.com Page: 5 2022/03/08...
NCLOSURE AND ONTROLS 3.1 S TART AND STOP OPERATION The Avisaro 4.0 starts with operation right after power on if an USB stick is inserted. Also, after re- inserting a USB stick, the operation starts automatically. 3.2 LED B LINK ODES There is one multicolor LED to signal states of the Avisaro device.
Jump to: Table of Content 3.4 E “4.0 S ” WAGO NCLOSURE WITH CONNECTOR Front with slot for USB stick. Matches are shown Reverse side shows the two WAGO connectors just for size reference: for data and power: Optional, a DIN rail fitting is available: WAGO connector are great with single wires.
Companion Software” .. “USB Storage” ether in this document, or in the overall “User Manual Serie 4.0” document. Alternatively, third party tools for Windows can be used to format large USB sticks. Please note: Avisaro can not support those third party tools.
Page 9
Jump to: Table of Content The appropriate memory size also depends on the intended use. Due to the technology, memory sticks with an extremely high capacity are typically less robust than smaller memory sizes. The loggers have a "ring memory" that can be optionally activated. If the memory stick becomes full (approx. less than 100MB free memory) the oldest files are deleted - this is a useful setting for some applications.
USB in “4.0 Sky” products USB Client in “4.0 Silver” products Most Avisaro devices are powered through the Mico-USB client port, however only for configuration. A stable regular operation is not guaranteed. Use the regular power supply for normal operation.
Heads-up: There are sometimes Micro USB cable which only do power supply, but not data. Those are used i.e. with mobile phones. If the Avisaro device is powered, but no data connection to the PC – just choose a different USB cable.
Jump to: Table of Content 5.3.3 Example: Wiring “differential” measurement The data logger allows for true differential measurement. The following diagram illustrates the wiring. 5.3.4 WAGO - 4x 0..10V Interface (“M49924” / “C49924”) Connector Interface Signal Direction WAGO A & 2 0..10V (+)
Page 13
Jump to: Table of Content Signal GND Signal GND WAGO B & 4 0..10V (+) 0..10V 0..10V (-) 0..10V (+) 0..10V (-) VCC (6..32V) Power Supply Power GND Cables are connected with the WAGO 734 series connectors. In most product configurations, those adapters are shipped with the box.
6.3 D ETAILED DOCUMENTATION This current document shows only selected parts of the full “Avisaro PC Companion Software” user manual. The motivation is to keep this document as compact as possible. Please find the extensive “Avisaro PC Companion Software” document in the support section of the...
6.5 D RIVER INSTALLATION If you connect the Avisaro Device to the PC using a Micro USB cable, a virtual COM port driver is installed. If this driver does not install automatically, you can download and install this manually: http://www.avisaro.de/de/40-PC-Treiber.html (German site) http://www.avisaro.com/en/40-ENG-PC-Driver.html...
SING THE OMPANION Click on “Write Config” to transmit changes in the PC tool to the Avisaro device. Click on “Read Config” to display the currently stored values (if you navigate between options, the latest settings are read of course automatically).
In most cases, devices are shipped with proper settings on this page. 6.8.1 Global HW settings ⇨ System functions Don’t touch those settings unless advised by technical support team from Avisaro. Global HW settings ⇨ Networking 6.8.2 Activate the network interface which is physically present.
Jump to: Table of Content ⇨ 4..20 6.9 I A / 0..10V NTERFACES The analog interfaces for 4..20mA and 0..10V are managed in the same settings page. 6.9.1 Sample Rate Select the desired sample rate in samples per seconds (hz). 6.9.2 Stream to In this point of time, only “Analog data (generic)”...
Jump to: Table of Content ⇨ 4..20 6.10 D A / 0..10V ROCESSING Settings for collection 0..10V or 4..20mA analog data. 6.10.1 Storage Format ⇨ Storage format This is the default setting. … Page: 19 2022/03/08...
Jump to: Table of Content 4x Current (mA)(NMEA) Storage format example with the setting above: 2022/03/02,15:45:33,332, $20MA, 9.979 mA, 0.761 mA, 0.001 mA,-0.001 mA 2022/03/02,15:45:34,331, $20MA, 9.980 mA, 0.730 mA,-0.001 mA, 0.001 mA 2022/03/02,15:45:35,330, $20MA, 9.980 mA, 0.742 mA,-0.001 mA, 0.000 mA 2x Current (mA)(NMEA) Storage format example with the setting: 2022/03/02,16:41:24,795, $20MA,...
Jump to: Table of Content No network forwarding Network (IP) Data are forwarded to the “Network (IP)” endpoint The same format is used as set in “Storage format” (PC companion version 2.65 and firmware version 2.65 or higher required) ⇨ USB S 6.11 D NDPOINTS TICK...
⇨ C 6.12 D NDPOINTS LOUD ETTINGS The Cloud features of the Avisaro devices are best described in separate application specific documents. Thus, here the settings are described briefly without the ‘large picture’ behind it. Page : 22...
Store & Collect Stored data are made available to be picked up by a Server Software. Parameter are: • User and Password • Device Name Typically, “Store&Collect” goes along with the “Avisaro Dashboard Software” (see separate documentation) Page: 23 2022/03/08...
There are three ways to update the firmware of the Avisaro 4.0 family: 1. Via USB Stick If the Avisaro 4.0 product has a USB Host port, a new firmware can be uploaded using a USB stick. See details below.
IRMWARE PDATE VIA SERVER INTERNET Avisaro Devices can be update remotely. This is a powerful service feature. To enable, navigate to “Data Endpoints”->“CLoud setting” and activate “Remote firmware update”: The update procedure is as follows: • Place the new firmware file - usually called “avi40up.bin” on the FTP server...
Page 26
30 seconds which is sensitive to power failure) Recommendations: • It is highly recommended to create a different user pointing to a different subdirectory for each Avisaro Data logger. This way, a firmware update can be directed to each Page : 26 2022/03/08...
Jump to: Table of Content ONTACT AND UPPORT Please contact Avisaro if there are any questions: Avisaro AG Grosser Kolonnenweg 18 E 30163 Hannover Germany Email: support@avisaro.com End of this documentation Page : 28 2022/03/08...