Download Print this page

Chapter1. Barcode Reader - Nautilus Hyosung MX8800 Manual

Hide thumbs Also See for MX8800:

Advertisement

Chapter1. Barcode Reader

Chapter1. Barcode Reader
Code
Problem Description
9708014
Fail to open Serial port.
9708030
Fail to create registry
9708031
Fail to read registry information
9708032
Fail to write registry information 1. Reset the Barcode SP
9708034
Fail to delete registry
information
9708042
Fail to start thread of the
BarCode SP
9708043
Fail to stop thread of the
BarCode SP
9708101
Cannot set to enable state on
the BarCode Reader
9708102
Cannot set to disable state on
the BarCode Reader
9708103
Cannot read a BarCode Data
from BarCode Reader
9708104
Detected a error on the
communication line(RS-232C)
9708105
encountered unexpected
timeout from firmware.
© 2014 Nautilus Hyosung Inc. All Rights Reserved.
Error Code Manual
Troubleshooting
1. Check whether the communication
cable and serial port are connected or
not.
2. Change Unit if error is continuous
1. Reset the Barcode SP
1. Reset the Barcode SP
1. Reset the Barcode SP
1. Reset the Barcode SP
1. Reset the Barcode SP
1. Check a barcode reader
2. Check a status of the communication
line
3. Reset the BarCode SP
4. Change Unit if error is continuous
1. Check a barcode reader
2. Check a status of the communication
line
3. Reset the BarCode SP
4. Change Unit if error is continuous
1. Check a barcode reader and barcode
image
2. Check a status of the communication
line
3. Reset the BarCode SP
4. Change Unit if error is continuous
1. Check a barcode reader
2. Check a status of the communication
line
3. Reset the BarCode SP
4. Change Unit if error is continuous
1 .SP Close and Open(Take the Log for
failure)
2. Restart the system
1-1

Hide quick links:

Advertisement