Electric heater Maxi Heat Digital

Pipe installation

Connect the heater into the pool system as shown in the diagram below. The outlet must not be connected to any tap or fitting
other than those specified.
The heater is equipped with G2¾" unions to be glued on PVC pipes with outer dimension Ø63 mm.
Note! Do not install a gate valve between the heater and the swimming pool (install a check valve instead).
Dosage of chlorine, acid or similar, must always be done after the heater to avoid corrosion.
Skimmer

Electric installation

All electric installations must be made by a qualified electrician according to the accompanied heater instructions.
The heater must be installed with a main supply on-off switch. We also recommend to install an earth fault relay.
Connect the heater as shown in the wiring diagram, see following pages 4 and 5. The heater shall be installed in such way
that it cannot be activated if the circulation pump is not working (sufficient flow), i.e. the power supply to the contactor must be
guided over the motor protection of the pump.
Do not connect the heater to an improper source of electricity.
Contact the local utility to obtain information about the correct power supply.
Voltage applied to the heater should not vary more than +5% to -10% to the model and rating plate specification.
For correct protection, follow this table
Part no
1510018
1510025, 1510030, 1510218
1510036, 1510224
1510045, 1510230
1510060, 1510236
1510072, 1510245
1510248, 1510260
(Part no, see rating plate on the heater.)
Pahlén AB, Box 728, SE-194 27 Upplands Väsby, Sweden
Tel. +46 8 594 110 50, Fax +46 8 590 868 80, e-mail: info@pahlen.se, www.pahlen.com
Jet Swim
Light
Drain
Filter
Pump
External fuse
32A
50A
63A
80A
100A
125A
160A
Inlet
Light
Check valve
Maxi Heat
By-pass
gate
Out
valve
Drain
In
Installation instruction