Download Print this page

Installation - Pahlen Aqua spa Manual

Hide thumbs Also See for Aqua spa:

Advertisement

Available languages

Available languages

Electric heater Aqua spa
Product description
For small pools and bubble baths.
Art. nr 141650 1,5kW, 141651 2kW, 141652 3kW.
The heater comes with an adjustable thermostat with a temperature range 0-45° C, overheating protection with a maximum
refractive temperature of 60° C and a flow switch that breaks voltage when the water flow is less than 90 l/min.
Casing is made of plastic and the electric cartridge of Incoloy 825. Connections are made of PVC for internal attachments to
PVC pipes Ø50 mm.
The heater must NOT be used in aggressive water, salt water or in pools with chlorine machine/salt chlorinator.
Technical data
Minimum flow:
90 l/min
Maximum flow:
300 l/min
Voltage:
220-240V, single phase
Max. overpressure:
1 bar
Max. temperature:
45°C
General information
To ensure good operation and long life of the electric heater,
it is important to follow the recommended values for water quality.
Total chlorine content:
max 3,5 mg/l (ppm)
Chloride (salt) content: max 250 mg/l (ppm)
pH-value:
7,2 - 7,6
Alkalinity:
60-120 mg/l (ppm)
Calcium hardness:
100-300 mg/l (ppm)
Iron:
max 0,1 mg/l *
Copper:
max 0,2 mg/l *
Manganese:
max 0,05 mg/l *
Phosphorus:
max 0,01 mg/l *
Nitrate:
max 50 mg/l *
Outside these values the product warranty does not apply.

Installation

The heater should be installed at least 200 mm below normal water level in the pool, see example.
Connection must be made with PVC tube Ø50mm (int. Ø42mm) with at least 200 mm straight length before and after the heater.
Note! The heater junction box should be facing upwards.
If the installation instructions are not followed, the product warranty is not valid.
Installation must be the kind that the heater cannot be self-drained if there is no pool circulation. Valves may not be installed so
that water flow through the heater can be completely switched off.
If a valve between the pool and the heater is required, this should be a check valve.
Please install a level guard in the pool so that the heater automatically switches off at low water level.
Installation example 1: Small pool
1
4
* Complies with EN 16713-3
3
3
5
8
Dimensions
Ø50
120
2
7
6
Ø50
Ø50
L>200
L>200
7
ENGLISH
187
200
NOTE!
Electric heater must
always be positioned
at least 200 mm below
the water level.
1. Skimmer
2. Inlet
3. Light
4. Pump
5. Filter
6. Electric heater
7. Check valve
8. Drain

Advertisement