Disposal; Technical Data; Information Requirements For Fan Coil Units; Dimensions - Daikin FWE03D Installation Manual

Fan coil units
Hide thumbs Also See for FWE03D:
Table of Contents

Advertisement

8 Disposal

8
Disposal
▪ Units are marked with the following symbol:
This means that electrical and electronic products may NOT be
mixed with unsorted household waste. Do NOT try to dismantle
the system yourself: the dismantling of the system, treatment of
the refrigerant, of oil and of other parts MUST be done by an
authorised installer and MUST comply with applicable legislation.
Units MUST be treated at a specialised treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed of
correctly, you will help to prevent potential negative consequences
for the environment and human health. For more information,
contact your installer or local authority.
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
Use proper tool for removing the screws. The product can be
disassembled as shown below.
4
8
24
20
1
23
3
25
18
2
26
11
27
16
7
17
19
FWE-D Recycle instruction list
Materials
Electrical part (fan motor +
capacitor)
Aluminium (fin) + copper (tube) +
galvanized steel (plate) + brass
Plastic
Plastic + metal
Plastic (frame) + plastic (net)
Galvanized steel
Galvanized steel + plastic foam
Plastic foam
9

Technical data

▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
Installation manual
26
9
22
6
5
12
10
21
14
13
15
Item
1
10
2, 18, 8, 22, 27
3, 17, 24
4
5, 9, 13, 14, 16, 20, 23, 25, 26
6, 7, 11, 12, 15, 19
21
▪ The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
9.1
Information requirements for fan
coil units
Follow the steps below to consult the Energy Label – Lot 21 data of
the unit and outdoor/indoor combinations.
1 Open the following webpage:
2 To continue, choose:
▪ "Continue to Europe" for the international website.
▪ "Other country" for a country related site.
Result: You are directed to the "Seasonal efficiency" webpage.
3 Under "Eco Design – Ener LOT 21", click "Generate your data".
Result: You are directed to the "Seasonal efficiency (LOT 21)"
webpage.
4 Follow the instructions on the webpage to select the correct
unit.
Result: When the selection is done, the LOT 21 datasheet can be
viewed as a PDF or a HTML webpage.
INFORMATION
Other documents (e.g. manuals, ...) can also be consulted
from the resulting webpage.
9.2

Dimensions

Horizontal outlook
460
400
394
316
https://energylabel.daikin.eu/
525
485
(mm)
FWE03~11D
Fan coil units
3P443944-5P – 2021.12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fwe04dFwe05dFwe06dFwe07dFwe08dFwe10d ... Show all

Table of Contents