Installing The Hardware - Honeywell S7999D1048 Manual

Combustion system operator interface display
Table of Contents

Advertisement

S7999D1048 COMBUSTION SYSTEM OPERATOR INTERFACE DISPLAY

INSTALLING THE HARDWARE

Mounting the S7999D
The S7999D can be mounted on the door panel of an electrical
enclosure.
1. Select the location on the door panel to mount the dis-
play; note that the device will extend into the enclosure at
least one inch past the mounting surface.
2. Provide an opening in the panel door 8" wide X 5 1/2"
high (for front panel mount) or 7 1/8" wide X 4 11/16"
high (for rear panel mount). See Fig. 1 or use cutout tem-
plates provided in Fig. 129 and Fig. 130.
3. Place the S7999D Display in the opening and use it as a
template to mark the location of the four mounting screw
holes. Remove the device.
4. Using pilot holes as guides, drill 1/4 in. holes through the
door panel.
5. Place the display in the opening, aligning the mounting
holes in the device with the drilled holes in the panel.
6. Secure the display to the panel with four #6-32 screws
and nuts provided.
7. Wire the 24 Vac power supply and the RS-485 cables
using the configuration and wiring diagrams in Fig. 3 to
Fig. 9.
8. Ensure the 8-pin connector plug is aligned with the
header pins when inserting the 8-pin connector plug
back onto the Display. Secure firmly
Installing the ControLinks™ and
Burner Control Hardware
Use the following ControLinks™ instructions to install the
system hardware: See Fig. 3 for wiring block diagram.
65-0321—01
— 65-0238 R7999 ControLinks™ Control Controller.
— 65-0239 ML7999 ControLinks™ Control Actuator.
— 65-0240 Q7999 Wiring Subbase.
— 65-0101 S7830 Expanded Annunciator.
— 65-0249 S7810M Modbus™ Module.
— 65-0084 Q7800 Wiring Subbase.
— 65-0109 R78xx Flame Amplifier
— 65-0089 ST7800 Purge Card
— 65-0090 S7800 KDM
— 65-0288 S7800A1142 KDM
— 65-1085 7800 SERIES Relay Modules
Installing the Universal Digital
Control Hardware
Use the following documents to install the UDC2500,
UDC3200, and UDC3500 hardware.
— 51-52-25-124 UDC2500 Quick Start Guide.
— 51-52-03-36 UDC2500 Specification.
— 51-52-25-127 UDC2500 Product Manual.
— 51-52-25-129 UDC3200 Quick Start Guide.
— 51-52-03-39 UDC3200 Specification.
— 51-52-25-119 UDC3200 Product Manual.
— 51-52-25-130 UDC3500 Quick Start Guide.
— 51-52-03-40 UDC3500 Specification.
— 51-52-25-120 UDC3500 Product Manual.
Refer to addendums at the end of this document for
configuration parameters specifically designed for the
application that the UDC controller provides.
4