Non-Standard Applications - Siemens SITRANS LC500 Operating Instructions Manual

Capacitance transmitters
Table of Contents

Advertisement

Non-standard applications

Applications outside the standard capabilities of the S-Series require a different design
configuration. These non-standard applications include:
Non-Standard Application
Non-metallic tanks with both conducting
and non-conducting liquids.
Non-conducting liquids in spherical and
horizontal-cylindrical tanks.
Highly corrosive materials requiring no
metallic wetted parts.
For more details on alternate configurations, see,
versions and application details on
Page 20
SITRANS LC500 – OPERATING INSTRUCTIONS
SITRANS LC500 Configuration
Use stilling well for second electrode reference.
Use a stilling well as linearizer.
Use flange mount with PFA Facing (7ML5517).
Appendix E: SITRANS LC500, alternate
page 84.
7ML19985GE04

Advertisement

Table of Contents
loading

Table of Contents