Preliminary Operations: Overview
Setting Frame C–CCP Shelf Configuration Switch
2

Figure 2-2: Backplane DIP Switch Settings

ALL SWITCHES ON (UP) EXCEPT MODEM_FRAME_ID_0
ON
OFF
2-4
The backplane switch settings behind the fan module nearest the breaker
panel should be set as shown in Figure 2-2.
The switch setting must be verified and set before power is applied to the
BTS equipment.
Starter Frame – all dip switches set to ON (UP)
S
Expansion Frame – all dip switches ON (UP) except
S
MODEM_FRAME_ID_0 OFF (DOWN)
OFF (DOWN)
EXPANSION
FRAME
SETTING
1X SC 4812T-MC Multicarrier BTS Optimization/ATP
ALL SWITCHES ON (UP)