Graco SoloTech i6 Repair And Parts Manual page 15

Peristaltic pumps
Table of Contents

Advertisement

Reassembly
Reassembly
Reassembly
Clean
Clean
Clean and
and Inspect
and
Inspect
Inspect All
All Parts
All
NOTICE
NOTICE
NOTICE
Use only genuine Graco replacement parts.
Non-standard parts will void your warranty and
may damage your equipment.
• Discard all used seals, gaskets and worn parts.
• Ensure that all new and existing parts are clean
and undamaged.
• Thoroughly clean all parts with a compatible
solvent and inspect for damage or wear. Replace
all gaskets, washers, worn parts and hardware as
necessary.
• Inspect the outer diameter of the pump roller. If the
surface has been worn, replace the roller.
• Inspect the bearings on the motor output shaft
(6). If the bearings are worn, replace the shaft
assembly.
• Inspect the shaft and bearing bore in the pump
housing (1). Ensure it is round, without grooves or
other signs of wear, and free of dirt, filings, or other
debris. A dirty or damaged bearing bore will greatly
reduce the life of the bearings.
• Inspect all metal parts for signs of wear or cracks.
Replace all worn parts.
NOTICE
NOTICE
NOTICE
The pump housing is aluminum. To help prevent
galling, inspect the bolt threads for foreign material
and clean or replace if necessary.
3A3367L
Parts
Parts
Install the
Install
Install
the Motor
the
Motor Output
Motor
Output Shaft
Output
1. Inspect the bearings and make sure that all
rotate freely and are seated against the shoulder
of the shaft (6).
2. Install the eccentric shaft key (56).
3. Coat the outer races of the shaft bearings and the
inner diameter of the housing with lithium-based
grease. Make sure there is no dirt or debris on
either the bearings or the housing.
4. Insert the shaft (6) into the pump housing (1) from
the front. Make sure that the bearings engage
the opening flush and straight. If necessary,
lightly tap the roller end of the shaft with a rubber
mallet until the shaft is firmly seated in the pump
housing.
Alternative
Alternative
Alternative Method
Method: Prop the housing so the front
Method
is facing up. Insert the shaft from the top down.
NOTICE
NOTICE
NOTICE
Do not force the shaft and bearings into the
pump housing. This may cause damage to the
bearings or the housing.
5. Install the bearing retaining ring (7) in front of the
outer bearing.
Repair
Shaft
Shaft
15

Advertisement

Table of Contents
loading

Table of Contents