2. When on:ti is displayed, press
ENTER to lock in the selection.
3. To set the ON time use the UP or
DOWN ARROW to scroll through the numerals 0-5
until the desired number appears in the first Minutes
(MM) field.
4. Press the ENTER button to lock in the selection.
The next MM number field to the right flashes, indicating
it is ready for programming.
NOTE:
The MM field is a 2-digit number.
A leading zero (0) must be entered in the first
field if the number of minutes is fewer than 10.
The highest number that can be set for the MM
field value is 59.
5. Use the UP or DOWN ARROW to scroll through the
numerals 0-9 until the desired number appears in
the second MM number field.
6. Press the ENTER button to lock in the selection.
The next number field to the right flashes indicating it is
ready to program the Seconds (SS) fields.
7. Repeat steps 3 - 6 to set the SS fields.
NOTE:
The Seconds (SS) field is a 2-digit number.
A leading zero (0) must be entered in the first
field if the number of seconds is fewer than 10.
The highest number that can be set for the SS
field value is 59.
The controller automatically switches to the OFF TIME
SETUP MODE.
3A2960A
Programming OFF TIME Duration
After setting the parameters for either Pressure (P),
Cycle (C) or Time (T) ON Modes, the OFF or PUMP
REST CYCLE must be set up.
To set the OFF Time:
1. Use the UP or DOWN ARROW to
scroll through the numerals 0-9
until the desired number appears
in the first Hours (HH) field.
2. Press ENTER to lock in the selec-
tion.
The next HH number field to the right flashes, indicating
it is ready for programming.
NOTE:
The HH field is a 2-digit number.
A leading zero (0) must be entered in the first
field if the number of hours is fewer than 10.
The highest number that can be set for the HH
field value is 99.
3. Use the UP or DOWN ARROW to scroll through the
numerals 0-9 until the desired number appears in
the second HH field.
4. Press the ENTER button to lock in the selection.
The next number field to the right flashes indicating it is
ready to program the Minutes (MM) fields.
5. Repeat steps 1 - 4 to set the MM fields.
NOTE:
The MM field is a 2-digit number.
A leading zero (0) must be entered in the first
field if the number of minutes is fewer than 10.
The highest number that can be set for the MM
field value is 59.
6. Press the ENTER button to lock in the last MM field.