5
5.1
Design
Supported products
Electrical data
Mobile interface
Environmental
specifications
Leica ComGate10, Technical Data
Technical Data
General Technical Data
Robust sheet steel housing with DIN rail mounting.
• MS60/TS60
• MS50/TM50/TS50
• TM30/TS30
• TS15
• TS16
• TPS1000/TPS1100/TPS1200
• GMX910
• GMX902
• Nivel210
• Nivel220
• DTM STS RS232 meteo sensors
• TP meteo sensor RS485
• Geotechnical Sensors in combination with Campbell Dataloggers.
• Warning devices, for example signal lamps or sirens. The ComGate10 contains two
coupling relays. Both coupling relays can be switched digitally to connect warning
devices.
One or two products can be connected to the ComGate10 in any combination.
Type
Voltage range
Nominal voltage
Current max.
Power consumption
Type
ComGate10
The following precautions must be taken before installing a ComGate10 router:
• Avoid direct solar radiation
• Protect the device from humidity, steam and aggressive fluids
• Guarantee sufficient circulation of air around the device
• The device is for indoor use only
Operating temperature [°C]
−25 to +70
External influences
Water, dust and sand
Humidity
ComGate10
12–48 V DC (−15 %/+20 %)
12 V DC, 24 V DC, 36 V DC and 48 V DC
0.42 A
5 W (no products are connected)
Mobile interface
GSM, GPRS, EDGE, UMTS, HSDPA, HSUPA and LTE
Storage temperature [°C]
−25 to +70
Protection
IP40 (IEC60529)
Protected against objects with a diameter bigger
than 1 mm. Not protected against water.
Up to 95 % (non condensing)
35