3.2
Power supply cable
3.3

Configuration

options
Leica ComGate10, Operation

Power Supply

a
b
c
014116_001
Step
Description
During the procedure the power supply should not be connected to the main
supply.
Connect the power supply to the power input of the ComGate10 by using
the terminal block.
1.
Connect the black wire of the power supply to the first connector (VGND) of
the terminal block.
2.
Connect the red wire of the power supply to the second connector (V+).
After the activation of the ComGate10 you have to wait until the
ComGate10 is initialised. The initialisation is finished when the Status LED
on the front panel of the wireless router has stopped blinking.
Configuration
The installation steps and screenshots in this chapter suit to the operating system
Windows 7. For other operating systems, steps and screenshots may vary.
Option
Configure with the stand-alone version of
the Leica ComBox Manager, which can be
installed from the Leica M-Com
ComBox/ComGate USB card.
Configure with the Leica GeoMoS Monitor
software, which includes the Leica
ComBox Manager.
a) VGND (black cable)
b) V+ (red cable)
c) Ground
Description
Only configuration
Configure and insertion of ComGate10
settings into the database of GeoMoS.
Required if a ComGate10 is used in a Leica
GeoMoS project.