Leica ComGate10 User Manual page 32

Table of Contents

Advertisement

Setup of the digital
I/O
Leica ComGate10, Operation
Drawing and description of the two coupling relays which can be used to connect
warning devices or restart the instrument from a remote position.
006193_001
DO1
DO2
006194_001
DO1
Normally Closed, it is connected when the relay coil is off.
DO2
Normally Open, it is connected when the relay coil is on.
Only DO1 should be used to connect a warning device.
DO2 should be used to switch the instrument off/on.
Relay specifications
• Limiting continuous current:
• Maximum switching voltage:
• Maximum switching capacity:
Power supply for instrument
• Instrument can be switched off/on automatically.
• Bridge to DO2 has to be set up.
• Use GeoMoS, Leica ComBox Manager or SMS for switching the instru-
ment.
• Switch box will be obsolete.
a
Max. current: 1 A
Max. switching voltage: 60 V AC
1 A
60 V DC, 42 V AC (Vrms)
60 W
a) For example:
GEV271
32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comgt10lweu

Table of Contents