2-7.
CONTACTORS
593
The following tests are performed with the wall circuit
breaker closed and the Power switch in the ON position.
Make connections before applying power, then take read-
ings. Remove power before removing meter leads, or
electrical shock may result.
1. With power applied, increase setpoint temperature setting allow-
ing heat contactor to activate.
Test Points
Heat Contactor
from terminal 34 to 35
from terminal 35 to 36
from terminal 34 to 36
Test Points
Primary Contactor
from terminal 27 to 28
from terminal 28 to 29
from terminal 27 to 29
If either contactor is defective, it must be replaced as follows:
1. Remove electrical power supplied to the fryer by unplugging
or opening the wall circuit breaker.
2. Remove only those wires directly connected to the contactor
being replaced. Label the wires.
3. Remove the two mounting screws on the base plate and
remove contactor.
4. Install the new contactor and tighten the two mounting
screws.
5. Connect the labeled wires to their respective positions.
6. Install the control panel.
7. Reconnect power to the fryer and test the fryer for proper
operation.
Model OE-100
SHOCK HAZARD
Results
The voltage
should read the
same at each
terminal.
Results
It should
correspond to
the voltage
rating stated on
the data plate.