Yale PR3301 Installation Instructions Manual

Yale PR3301 Installation Instructions Manual

Parallel rigid arm door closers

Advertisement

Quick Links

Parallel Rigid Arm Door Closers (PR)
Holder-Stop Door Closers
Hold-Open Door Closers
Additional Closer Options:
- "DL" indicates Delayed Action closing.
- "H" indicates Hold-Open function components are handed.
- "T" indicates Thumbturn actuated Holder-Stop control.
Optional Accessories:
- 3148 Dropplate
- 293L, 293S, 890, 891 Soffit Plate Accessories.
NOTE: For special applications a separate door and frame preparation template is packed with these instructions. In those
cases, use this instruction sheet for installation sequence and closer adjustments only.
Closer mounts on opposite to hinge (push) side of door. PR3301 Parallel Rigid Non Hold Open arm illustrated. Slim Line Cover shown.
Right Hand Door – RH
Left Hand Reverse – LHR
Closer mounts on opposite to hinge (push) side of door. CLP3501 CloserPlus arm illustrated. Full Cover shown.
Right Hand Door – RH
Left Hand Reverse – LHR
Closer mounts on opposite to hinge (push) side of door. CLP3101T CloserPlus arm with Thumbturn Hold Open illustrated.
Closer Cover not shown. 293L accessory required for this application (supplied separately).
Right Hand Door – RH
Left Hand Reverse – LHR
Installation Instructions
80-9303-2209-010 (04-06)
An incorrectly installed or improperly
adjusted door closer can cause
property damage or personal injury.
These instructions should be followed
to avoid the possibility of
misapplication or misadjustment.
Standard Frame Installation
See Pages 3 and 4
Narrow Frame Installation
890 and 891 accessories required for this application (supplied separately).
See Pages 3 and 4
Flush Partition Installation
See Pages 3 and 4
Model Numbers Included:
PR3301/ PR330X
PR3311/ PR331X
PR3501/ PR350X
PR3511/ PR351X
3321(T) / 332X(T)
3521(T) / 352X(T)
Note 'X' Designates Size 2, 3, 4, 5, or 6
Left Hand Door – LH
Right Hand Reverse – RHR
Left Hand Door – LH
Right Hand Reverse – RHR
Left Hand Door – LH
Right Hand Reverse – RHR

Advertisement

loading

Summary of Contents for Yale PR3301

  • Page 1 Standard Frame Installation Closer mounts on opposite to hinge (push) side of door. PR3301 Parallel Rigid Non Hold Open arm illustrated. Slim Line Cover shown. See Pages 3 and 4 Right Hand Door –...
  • Page 2 Power Soffit 293S Block Optional Components Adjustment Plate (provided) Accessories Backcheck Valve Shaft For Blade Stop 891 Spa er Delay Valve Main Arm (Optional) Screw For Frame or Blade Stop 890 Bracket Main Arm Closer Closer Body For Flush Partition 293L Bracket Latch Valve Sweep Valve...
  • Page 3: Installation Instructions

    100°- 105°- 115°- 110°- 120°- 90° 95° 100° 105° 110° 120° 115° 180° 1-1/4 3-3/4 (32) (95) (mm) Start (wrench) here PR3301/PR3501 9-1/2 (241) (178) (mm) 4-7/8 3-1/2 2-1/4 5-5/8 4-1/8 2-7/8 Butt Rotate Hinges (124) (89) (57) (143) (105)
  • Page 4: Standard Frame

    Standard Frame Notes: 2-3/4 Do Not Scale Drawing. (70) Left Hand Door Shown. 5/16* Same dimensions apply for Right Hand (10) (51) Door measured from centerline of pivot point. Dimensions are in inches (mm). 2-1/16 7/16 See Page 3 for A & B dimension values. (52) (11) *Use 9/16 (14) in openings...
  • Page 5 3148 Drop Plate Mounting Holes Standard Frame C L Hinge or Pivot 1-1/4 (32) (102) (102) (102) 3148 Drop Plate 5/16 Narrow Frame *NOTE: This dimension must be Hinge or taken from the same surface that Pivot the Soffit Plate is fastened to. 890 Bracket 1-1/4* (32)
  • Page 6: Unit Adjustment

    Unit Adjustment Closing Power Adjustment– Opening Cycle Using “Power Adjustment Chart” from Page 3, select the “Backcheck” valve controls the strength of cushioning in correct number of turns for power adjustment shaft that Backcheck Range. NEVER close this valve completely – it corresponds with the installation.