INSTALLATION AND OPERATING REQUIREMENTS

Install at a minimum 6 inches (152 mm) away from any wall to reduce dust or
particle build up.
Please wear personal protection equipment during installation (gloves, goggles, etc.).
Install plates take up at most, 9
that can be damaged around or above the unit inside the ceiling hole.
Do not install in a bathroom with a bathtub and/or shower where it is exposed to
high humidity.
Install at least 5 feet (1.5 m) away from any ventilation fan.
Do not install on a slanted ceiling. It may affect the performance of the nanoe™ X.
Note
Please use the template on the back cover to trace the hole size in the ceiling.
This product is for residential and commercial use. Installing this product in a
restroom with no shower and bathtub is permitted. In the case of residential
bathrooms with a shower and/or bathtub, installation is not permitted due to high
humidity.

INSTALLATION

Make a Ø 6 inch (152 mm) hole in the
1
ceiling and take out the conduit wires
more than 15 ¾ inches (400 mm) from
the ceiling. Do not attempt to install in
an opening larger than 6
(161 mm) in diameter.
Hole
Remove the screw ST4X12 and slide to
3
release the junction cover.
Screw ST4X12
Over 6 inches (152 mm)
/
1
8
/
inches
3
8
The suitable drywall thickness
is ¼ inches
1 inch
(6 mm
25 mm).
Slide in this direction
Junction cover
inches (233 mm). Make sure there is nothing
Pull the tab upwards to remove
2
the grille.
Open one of the knock-out holes
4
(two options) on the junction cover.
Over 6 inches (152 mm)
Tab
Grille
Top knock-out hole
Side knock-out hole
Junction cover
5