<octet-string>COSEM logical device name of the meter</octet-string>
<octet-string>COSEM logical name of the push setup object</octet-string>
<octet-string>COSEM logical name of profile</octet-string>
<array>
<structure>capture object 1</structure>
...
<structure>capture object m</structure>
</array>
<array>
<structure>profile buffer entry 1</structure>
...
<structure>profile buffer entry n</structure>
</array>
<array>
<structure>unit and scaler for register 1 stored in profile</structure>
...
<structure>unit and scaler for register m stored in profile</structure>
</array>
Each capture object must contain the following elements:
<long-unsigned>interface class ID</long-unsigned>
<octet-string>COSEM logical name</octet-string>
<integer>attribute index</integer>
<long-unsigned>data index</long-unsigned>
(see [2] 4.3.6)
Each profile buffer entry must contain the following elements:
<octet-string>timestamp</octet-string>
<some datatype>value</some data type>
<some datatype>value</some data type>
<some datatype>value</some data type>
...
(see [2] 4.3.6)
Each unit and scaler object contains the following elements:
<integer>scaler</integer>
<enum>unit</enum>
(see [2] 4.3.2)