The ripple control signal receiver and the I/Os terminal of the inverter can be
gram - 3 relays
connected to one another in accordance with the connection diagram.
If the distance between the inverter and the ripple control signal receiver ex-
ceeds 10 m, at least a CAT 5 cable is recommended and the shield must be con-
nected at one end to the push-in terminal of the data communication area
(SHIELD).
(1)
(2)
Use the preconfigured file for 3-relay mode:
1
2
3
The settings for 3-relay mode are stored.
Ripple control signal receiver with 3 relays, for effective power limiting.
I/Os of the data communication area.
Download the file (.fpc)
Upload the file (.fpc) in the "I/O Power Management" menu using the "Im-
port" button.
Click on the "Save" button.
under 3-relay mode
onto the end device.