Tray Setting
Both Side Adjustment
Gap Adjustment(Part2)
7. Measure the gap between the front
and back side at each point of [a] to
[d] on the [back] side
of printed chart to
acquire the adjustment
data
✓ The figure shows
an example to
measure [a]. the
scale resolution is
0.5mm
✓ The black lines in
the figure indicate
the front side and
the blue lines indicate the
back side
✓ You can enter a value in
0.1mm increments
✓ For example, when [a] scale
is misaligned upward 1.5mm
from the one on the front
side as shown in the figure,
press in order of [1][5]
[+/-] and enter -1.5 to
correct and move
downward the blue line
on he back side by
1.5mm
✓ When you count the
number of
can confirm which paper
tray was selected for
print
marks, you
紙盤設定
間隙調整(第二部份)
7. 量度測試表反面[a]到[d]各點和正面影像
的偏差值
25
兩面調整
✓ 圖解中是[a]點的例
子,每條尺度代表
0.5mm
✓ 圖解中的黑線尺度代表
正面, 藍線代表反面
✓ 可輸入以0.1mm為單
位的準確度
✓ 圖解中,反面[a]點的影
像(藍線)和正面[a]點
影像(黑線)的差距高出
了1.5mm
✓ 測試表中
符號的數量
代表選取的紙盤