Advanced Menu (Device Configuration Menu)
The Advanced Menu includes the parameters described in Table 7.
Table 7 The default settings of Advanced Menu
Parametr
English
The Menu Exit – enables exit from menu.
Note: This parameter cannot be edited.
To exit from menu:
In Advanced Menu select P000.
Confirm the selection, push the right button.
Wire Feed Speed (WFS) units – enables change WFS units:
CE (factory default) = m/min;
US = in/min.
Crater Delay - this option is used to skip the Crater sequence
when making short tack welds. If the trigger is released before
the timer expires, Crater will be bypassed and the weld will end.
If the trigger is released after the timer expires, the Crater
sequence will function normally (if enabled).
OFF (0) to 10.0 seconds (default = OFF)
Arc Start/Loss Error Time - This option can be used to
optionally shut off output if an arc is not established, or is lost for
a specified of time. Error 269 will be displayed if the machine
times out. If the value is set to OFF, machine output will not be
turned off if an arc is not established or arc is lost. The trigger
can be used to hot feed the wire (default). If a value is set, the
machine output will shut off if an arc is not established within the
specified amount of time after the trigger is pulled or if the
trigger remains pulled after an arc is lost. To prevent nuisance
errors, set Arc Start/Loss Error Time to an appropriate value
after considering all welding parameters (run-in wire feed
speed, weld wire feed speed, electrical stick out, etc).
OFF (0) to 10.0 seconds (default = Off)
Note: This parameter is disabled while welding in Stick, TIG or
Gouge.
Feedback Persist – determines how feedback values are
displayed following a weld:
"No" (factory default) – last recorded feedback values will
blink for 5 seconds following a weld, then return to present
display mode.
"Yes" – last recorded feedback values will blink indefinitely
following a weld until a Control or Button is touched, or an
arc is struck.
Brightness Control - enables the brightness level.
Adjust range: from 1 to +10, where 5 is default.
Restore Factory Settings – to restore Factory Settings:
Use the right button to confirm the selection.
Use the right control to select "YES".
Use the right button to confirm the selection.
Note: After the device has been restarted the P097 is "NO".
Show Test Modes– uses for calibration and tests. To use the
Test Modes:
On the right display is shown "LOAD".
Use the right button to confirm the selection.
On the right display is shown "DONE"
Note: After the device has been restarted the P099 is "LOAD".