iUP-200A/201A
The universal programmer accepts one of four different AC line voltages. Before
plugging in the universal programmer and turning it on, you should set it to the ap
propriate available line voltage as follows:
1. Verify that the universal programmer is unplugged from its power source.
2. Note the four line voltage settings summarized in a table printed on the back
panel of the universal programmer. (Figure 2-1 shows the switches set for
120 VAC.)
Set SW1 and SW2 for the line voltage to be used to power the unit ( verify that
the letters are visible on the switches) as follows:
•
100 VAC: set both SW1 and SW2 to position A.
•
120 VAC: set SW1 to position A and SW2 to position B.
•
220 VAC: set SW1 to position B and SW2 to position A.
•
240 VAC: set both SW1 and SW2 to position B.
3. If the correct power fuse is installed, plug the universal programmer into a
power source of the selected voltage and turn it on. (Checking and replacing
the power fuse is described in the next section.)
Checking and Replacing Power Fuse
Only a qualified technical person should check or replace the
power fuse.
W A R N IN G 1
Figure 2-1 Setting Line Voltage
Preparation for Use
LINE VOLTAGE
SELECTION SWITCHES
0144
2-3