iUP-200A/201A
The universal programmer accepts one of four different AC line voltages. Before
plugging in the universal programmer and turning it on, you should set it to the ap­
propriate available line voltage as follows:
1. Verify that the universal programmer is unplugged from its power source.
2. Note the four line voltage settings summarized in a table printed on the back
panel of the universal programmer. (Figure 2-1 shows the switches set for
120 VAC.)
Set SW1 and SW2 for the line voltage to be used to power the unit ( verify that
the letters are visible on the switches) as follows:
100 VAC: set both SW1 and SW2 to position A.
120 VAC: set SW1 to position A and SW2 to position B.
220 VAC: set SW1 to position B and SW2 to position A.
240 VAC: set both SW1 and SW2 to position B.
3. If the correct power fuse is installed, plug the universal programmer into a
power source of the selected voltage and turn it on. (Checking and replacing
the power fuse is described in the next section.)

Checking and Replacing Power Fuse

Only a qualified technical person should check or replace the
power fuse.
W A R N IN G 1
Figure 2-1 Setting Line Voltage