Wireless type
Table of Contents

Advertisement

12-3. MUCF-C18UV-
OUTDOOR UNIT
OPERATING PROCEDURE
1. Removing the cabinet
(1) Remove the screws fixing the cabinet.
(2) Remove the screw fixing the service panel.
(3) Remove the service panel, and remove the screw from
the insides.
(4) Remove the cabinet.
Photo 2
Screws
2. Removing the electrical parts
(1) Remove the cabinet . (Refer to 1)
(2) Remove the following parts .
•Compressor capacitor (C1)
•Outdoor fan capacitor (C2)
•Terminal block
•Fan motor relay (X 1)(For MUCF-C24UV)
•Contactor (52 C) (For MUCF-C24UV)
MUCF-C24UV-
E1
E1
Photo 1
Service
panel
Screw
Photo 3
Fan motor
relay
Contactor
Outdoor fan
capacitor
Compressor
capacitor
41
PHOTOS
Terminal block
Fan motor lead
connector
Screws