Mitsubishi Electric MCF-C13UV-E1 Service Manual page 29

Wireless type
Table of Contents

Advertisement

PROGRAM TIMER
The OFF timer and ON timer can be used in combination.
"
" and "
" display show the order of the OFF timer and ON timer operation.
(Example 1) The current timer is 8:00 PM.
The unit turns off at 11:00 PM, and on at 6:00 AM.
NOTE : TIMER setting will be cancelled by power failure or breaker functioning.
9-7. EMERGENCY-TEST OPERATION
In case of test run operation or emergency operation, use the EMERGENCY OPERATION switch on the front of the
indoor unit. Emergency operation is available when the remote controller is missing, has failed or the batteries of remote
controller run down. The unit will start and the OPERATION INDICATOR lamp will light.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan speed runs at
High speed and the system is in continuous operation. (The thermostat is ON.)
After 30 minutes of test run operation the system shifts to EMERGENCY COOL MODE with a set temperature of 24°C.
The fan speed shifts to Med. speed.
The coil frost prevention works even in emergency operation.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO (
Emergency operation continues until the EMERGENCY OPERATION switch is pressed again or the unit receives any sig-
nal from the remote controller. In case of latter normal operation will start.
NOTE : Do not press the EMERGENCY OPERATION switch during normal operation.
EMERGENCY
OPERATION switch
9-8. AUTO RESTART FUNCTION
When the indoor unit is controlled with the remote controller, the operation mode, set temperature, and the fan speed
are memorized by the auto restart P.C. board.
The "AUTO RESTART" function sets to work the moment the power has restored after power failure. Then, the unit will
restart automatically. However if the unit is operated in "I FEEL CONTROL" mode, before power failure, the operation is
not memorized. In "I FEEL CONTROL" mode, the operation is decided by the initial room temperature.
:
NOTE
•The operation settings are memorized when 10 seconds have passed after the remote controller was operated.
•If the main power is turned off or a power failure occurs while AUTO START/ STOP timer is active, the timer setting is
cancelled.
•If the unit has been off with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is off.
•To prevent breaker off due to the rush of starting current, systematize other home appliances not to turn on at the
same time.
•When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting
current by adding to the system that allows the units to start one by one.
(Example 2) The current time is 11:00 AM.
PM
AM
• The following indication applies
regardless of shape of the indicator.
Press once
Press once again
29
The unit turns on at 5:00 PM, and off at 9:00 PM.
) mode.
OPERATION INDICATOR lamp
<Cool>
<Stop>
PM
PM

Advertisement

Table of Contents
loading

Table of Contents