Mitsubishi Electric MCF-C13UV-E1 Service Manual page 20

Wireless type
Table of Contents

Advertisement

PERFORMANCE DATA
COOL operation
MCF-C18UV -
: MUCF-C18UV -
E1
CAPACITY:5.00(kW) SHF:0.68 INPUT:2180(W)
INDOOR INDOOR
DB(:) WB(:)
Q
SHC SHF
21
18
5.88 2.94 0.50
21
20
6.13 2.33 0.38
22
18
5.88 3.17 0.54
22
20
6.13 2.57 0.42
22
22
6.38 1.91 0.30
23
18
5.88 3.41 0.58
23
20
6.13 2.82 0.46
23
22
6.38 2.17 0.34
24
18
5.88 3.64 0.62
24
20
6.13 3.06 0.50
24
22
6.38 2.42 0.38
24
24
6.70 1.74 0.26
25
18
5.88 3.88 0.66
25
20
6.13 3.31 0.54
25
22
6.38 2.68 0.42
25
24
6.70 2.01 0.30
26
18
5.88 4.11 0.70
26
20
6.13 3.55 0.58
26
22
6.38 2.93 0.46
26
24
6.70 2.28 0.34
26
26
6.90 1.52 0.22
27
18
5.88 4.35 0.74
27
20
6.13 3.80 0.62
27
22
6.38 3.19 0.50
27
24
6.70 2.55 0.38
27
26
6.90 1.79 0.26
28
18
5.88 4.58 0.78
28
20
6.13 4.04 0.66
28
22
6.38 3.44 0.54
28
24
6.70 2.81 0.42
28
26
6.90 2.07 0.30
29
18
5.88 4.82 0.82
29
20
6.13 4.29 0.70
29
22
6.38 3.70 0.58
29
24
6.70 3.08 0.46
29
26
6.90 2.35 0.34
30
18
5.88 5.05 0.86
30
20
6.13 4.53 0.74
30
22
6.38 3.95 0.62
30
24
6.70 3.35 0.50
30
26
6.90 2.62 0.38
31
18
5.88 5.29 0.90
31
20
6.13 4.78 0.78
31
22
6.38 4.21 0.66
31
24
6.70 3.62 0.54
31
26
6.90 2.90 0.42
32
18
5.88 5.52 0.94
32
20
6.13 5.02 0.82
32
22
6.38 4.46 0.70
32
24
6.70 3.89 0.58
32
26
6.90 3.17 0.46
NOTE
Q : Total capacity (kW)
SHC : Sensible heat capacity (kW) INPUT : Total power input (W)
E1
21
INPUT
Q
SHC SHF
1744
5.63 2.81 0.50
1831
5.88 2.23 0.38
1744
5.63 3.04 0.54
1831
5.88 2.47 0.42
1897
6.15 1.85 0.30
1744
5.63 3.26 0.58
1831
5.88 2.70 0.46
1897
6.15 2.09 0.34
1744
5.63 3.49 0.62
1831
5.88 2.94 0.50
1897
6.15 2.34 0.38
1984
6.45 1.68 0.26
1744
5.63 3.71 0.66
1831
5.88 3.17 0.54
1897
6.15 2.58 0.42
1984
6.45 1.94 0.30
1744
5.63 3.94 0.70
1831
5.88 3.41 0.58
1897
6.15 2.83 0.46
1984
6.45 2.19 0.34
2093
6.70 1.47 0.22
1744
5.63 4.16 0.74
1831
5.88 3.64 0.62
1897
6.15 3.08 0.50
1984
6.45 2.45 0.38
2093
6.70 1.74 0.26
1744
5.63 4.39 0.78
1831
5.88 3.88 0.66
1897
6.15 3.32 0.54
1984
6.45 2.71 0.42
2093
6.70 2.01 0.30
1744
5.63 4.61 0.82
1831
5.88 4.11 0.70
1897
6.15 3.57 0.58
1984
6.45 2.97 0.46
2093
6.70 2.28 0.34
1744
5.63 4.84 0.86
1831
5.88 4.35 0.74
1897
6.15 3.81 0.62
1984
6.45 3.23 0.50
2093
6.70 2.55 0.38
1744
5.63 5.06 0.90
1831
5.88 4.58 0.78
1897
6.15 4.06 0.66
1984
6.45 3.48 0.54
2093
6.70 2.81 0.42
1744
5.63 5.29 0.94
1831
5.88 4.82 0.82
1897
6.15 4.31 0.70
1984
6.45 3.74 0.58
2093
6.70 3.08 0.46
SHF : Sensible heat factor
OUTDOOR DB(:)
25
INPUT
Q
SHC SHF
1831
5.40 2.70 0.50
1940
5.70 2.17 0.38
1831
5.40 2.92 0.54
1940
5.70 2.39 0.42
2017
6.00 1.80 0.30
1831
5.40 3.13 0.58
1940
5.70 2.62 0.46
2017
6.00 2.04 0.34
1831
5.40 3.35 0.62
1940
5.70 2.85 0.50
2017
6.00 2.28 0.38
2093
6.30 1.64 0.26
1831
5.40 3.56 0.66
1940
5.70 3.08 0.54
2017
6.00 2.52 0.42
2093
6.30 1.89 0.30
1831
5.40 3.78 0.70
1940
5.70 3.31 0.58
2017
6.00 2.76 0.46
2093
6.30 2.14 0.34
2202
6.60 1.45 0.22
1831
5.40 4.00 0.74
1940
5.70 3.53 0.62
2017
6.00 3.00 0.50
2093
6.30 2.39 0.38
2202
6.60 1.72 0.26
1831
5.40 4.21 0.78
1940
5.70 3.76 0.66
2017
6.00 3.24 0.54
2093
6.30 2.65 0.42
2202
6.60 1.98 0.30
1831
5.40 4.43 0.82
1940
5.70 3.99 0.70
2017
6.00 3.48 0.58
2093
6.30 2.90 0.46
2202
6.60 2.24 0.34
1831
5.40 4.64 0.86
1940
5.70 4.22 0.74
2017
6.00 3.72 0.62
2093
6.30 3.15 0.50
2202
6.60 2.51 0.38
1831
5.40 4.86 0.90
1940
5.70 4.45 0.78
2017
6.00 3.96 0.66
2093
6.30 3.40 0.54
2202
6.60 2.77 0.42
1831
5.40 5.08 0.94
1940
5.70 4.67 0.82
2017
6.00 4.20 0.70
2093
6.30 3.65 0.58
2202
6.60 3.04 0.46
20
27
Q
INPUT
SHC SHF
1918
5.20 2.60 0.50
1984
5.50 2.09 0.38
1918
5.20 2.81 0.54
1984
5.50 2.31 0.42
2071
5.75 1.73 0.30
1918
5.20 3.02 0.58
1984
5.50 2.53 0.46
2071
5.75 1.96 0.34
1918
5.20 3.22 0.62
1984
5.50 2.75 0.50
2071
5.75 2.19 0.38
2158
6.10 1.59 0.26
1918
5.20 3.43 0.66
1984
5.50 2.97 0.54
2071
5.75 2.42 0.42
2158
6.10 1.83 0.30
1918
5.20 3.64 0.70
1984
5.50 3.19 0.58
2071
5.75 2.65 0.46
2158
6.10 2.07 0.34
2267
6.40 1.41 0.22
1918
5.20 3.85 0.74
1984
5.50 3.41 0.62
2071
5.75 2.88 0.50
2158
6.10 2.32 0.38
2267
6.40 1.66 0.26
1918
5.20 4.06 0.78
1984
5.50 3.63 0.66
2071
5.75 3.11 0.54
2158
6.10 2.56 0.42
2267
6.40 1.92 0.30
1918
5.20 4.26 0.82
1984
5.50 3.85 0.70
2071
5.75 3.34 0.58
2158
6.10 2.81 0.46
2267
6.40 2.18 0.34
1918
5.20 4.47 0.86
1984
5.50 4.07 0.74
2071
5.75 3.57 0.62
2158
6.10 3.05 0.50
2267
6.40 2.43 0.38
1918
5.20 4.68 0.90
1984
5.50 4.29 0.78
2071
5.75 3.80 0.66
2158
6.10 3.29 0.54
2267
6.40 2.69 0.42
1918
5.20 4.89 0.94
1984
5.50 4.51 0.82
2071
5.75 4.03 0.70
2158
6.10 3.54 0.58
2267
6.40 2.94 0.46
DB: Dry-bulb temperature
WB: Wet-bulb temperature
30
INPUT
2006
2071
2006
2071
2158
2006
2071
2158
2006
2071
2158
2267
2006
2071
2158
2267
2006
2071
2158
2267
2333
2006
2071
2158
2267
2333
2006
2071
2158
2267
2333
2006
2071
2158
2267
2333
2006
2071
2158
2267
2333
2006
2071
2158
2267
2333
2006
2071
2158
2267
2333