Yoshitake DP-200 Series Manual page 3

Table of Contents

Advertisement

Performance and specifications of coil
Rated voltage
Allowable fluctuation
Rated current
Starting current
Insulation class
Protective structure
Ingress protection code
Insulation resistance
Withstand voltage test
• Available with coil equipped with a terminal box (made of plastic) upon request.
Caution
When using the solenoid valve to pilot piping of constant water level valve, select direct type or pilot type
in accordance with the instruction from constant water level valve manufacturer. If there is no instruction
from the manufacturer, we recommend selecting direct type DD-3-8N for the pilot piping below size 50A of
constant water level valve, and selecting pilot type DP-200-N for the pilot piping above size 65A of
constant water level valve
1. Please collate the attached nameplate with the specifications of the ordered model.
※If they are different, stop use and contact us
2. Make sure to confirm the specifications of constant water level valve before use.
※Constant water level valve or solenoid valve might not work properly depending on the
types of constant water level valve and solenoid valve or the piping conditions.
AC 100 / 200 V selective type
0.42/ 0.21 A
1.64 / 0.82 A
Please confirm that the indications on the product correspond with the specifications
of the ordered product model before use.
* If they are different, do not use the product and contact us.
.
50 / 60 Hz common
Rated voltage -5% to +10%
Insulation class H
Dust tight, Splash proof
IP64 (JIS C0920)
50 MΩ and more / 500 V megger
1500 V/min
Warning
2
AC 110 / 220 V selective type
0.38 / 0.19 A
1.48 / 0.74 A
■EPDT-266c■

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-200Dp-200f