rouBleshooting
Symptom
LCD does not illuminate on
the control panel when the
ON/OFF switch is in the
ON position.
Rollers do not turn.
Laminated items are
curling.
Adhesive deposited on
rollers.
Unsatisfactory laminate
adhesion.
Page 7-2
Possible Cause
Laminator not connected to electrical
supply.
Circuit Breaker tripped.
Infrared eyes blocked.
Feed tray interlock latch not in place.
Tension between the top and bottom film
roll is unequal.
Speed setting too slow.
Top and bottom film webs not aligned.
Laminate improperly loaded.
Insufficient roller pressure.
Laminate improperly loaded.
Rollers require cleaning.
Laminated item unsuitable for adhesion.
640t – Installation and Operating Instructions
Corrective Action
Insert attachment plug into receptacle.
Reset Circuit Breaker.
Unblock infrared eyes.
Slide interlock latch all the way to the left
into the side frame.
Adjust tension per "Film Tension" on page
6-10 .
Slightly speed up laminator.
Align film webs per "Film Alignment" on
page 6-10 .
Load film per "Loading Film" on page 6-2.
Adjust the roller pressure.
Load film per procedure outlined per
"Loading Film" on page 6-2.
Clean rollers per Cleaning the Rollers
page 7-1.
Item may be dirty or may have non-
porous surface that is extremely difficult
to laminate.

Advertisement