Annunciations & Alerts
giA 63W messAge Advisories (Cont.)
Message
G/S1 SERVICE – G/S1 needs
service. Return unit for repair.
G/S2 SERVICE – G/S2 needs
service. Return unit for repair.
geA 71 messAge Advisories
Message
GEA1 CONFIG – GEA1 config error.
Config service req'd.
GEA2 CONFIG – GEA2 config error.
Config service req'd.
MANIFEST – GEA1 software
mismatch, communication halted.
MANIFEST – GEA2 software
mismatch, communication halted.
gtx 33/33d messAge Advisories
Message
XPDR1 CONFIG – XPDR1 config
error. Config service req'd.
XPDR2 CONFIG – XPDR2 config
error. Config service req'd.
MANIFEST – GTX1 software
mismatch, communication halted.
MANIFEST – GTX2 software
mismatch, communication halted.
82
Garmin G1000 Cockpit Reference Guide for the Socata TBM 850
Comments
A failure has been detected in glideslope
receiver 1 and/or receiver 2. The receiver may
still be available. The G1000 system should be
serviced when possible.
Comments
The GEA1 configuration settings do not match
those of backup configuration memory. The
G1000 system should be serviced.
The GEA2 configuration settings do not match
those of backup configuration memory. The
G1000 system should be serviced.
The #1 GEA 71 has incorrect software installed.
The G1000 system should be serviced.
The #2 GEA 71 has incorrect software installed.
The G1000 system should be serviced.
Comments
The transponder configuration settings do not
match those of backup configuration memory.
The G1000 system should be serviced.
The transponder configuration settings do not
match those of backup configuration memory.
The G1000 system should be serviced.
The transponder has incorrect software installed.
The G1000 system should be serviced.
The transponder has incorrect software installed.
The G1000 system should be serviced.