Wiring - Furuno DS-60 Installation Manual

Doppler sonar
Hide thumbs Also See for DS-60:
Table of Contents

Advertisement

2.

WIRING

Refer to the interconnection diagram at the back of this manual to connect cables.
100-240 VAC
(DPYC-2.5)
DS-340
(CO-SPEVV-SB-C)
ANALOG VOLTAGE OUT (TTYCS-1)
ANALOG CURRENT OUT (TTYCS-1)
KP IN/OUT (TTYCS-1, x2)
ANALOG METER OUT (TTYCYS-1Q, x2)
LOG/CONTACT, 200 pulse (DPYCY-1.5, x4)
IEC61162/IN (TTYCS-1, x3)
IEC61162/OUT (TTYCS-1, x5)
Precautions for cable installation
Observe the following guidelines to prevent noise, interference problem.
• The transducer cable carries very weak signals (amplitude less than 0.1 μV), which
are easily interfered by noise. The need for a good ground cannot be overempha-
sized.
• Locate DS-60 cables away from the transmission antenna cable or radio equip-
ment.
• Locate the DS-60 cables away from the power cables mentioned below. Also, sep-
arate cables at least 400 mm when the cables are run parallel with power cables.
• Cable carrying more than a few kilowatts power to fluctuating loads
• Cable carrying switching waves generated by thyristor, etc.
Distributor
DS-610
ALARM SYSTEM
DIGITAL OUT
DIGITAL OUT
*The cable length between DS-620 and DS-610 must be less than 500 m.
Note: For details of JIS (Japan Industrial Standard) cables, see APPENDIX 2.
Remote Controller RD-501/
Dimmer Controller RD-502
TTYCYS-4
Display Unit
(main)
DS-600
TTYCYS-4 or TTYCS-4
(Max. 150 m)
Display Unit (sub) DS-600, RD-20/50 (x5)
Junction Box
DS-640 (option)
TTYCY-4S*
TTYCY-4S*
DPYCY-4.0*
DPYCY-4.0*
Transducer cable
(30 m/40 m/50 m/60 m)
Transceiver Unit
DS-620
Transducer
DS-630/631
2-1