Thru-Hull Temperature Sensor T-02Msb, T-03Msb - Furuno Network Sounder DFF3 Operator's Manual

Furuno network sounder operator's manual
Hide thumbs Also See for Network Sounder DFF3:
Table of Contents

Advertisement

1.5.2

Thru-hull temperature sensor T-02MSB, T-03MSB

Select a suitable mounting location considering the following points:
• Select a mid-boat flat position. The sensor does not have to be installed perfectly perpendicular.
However, the location should not be such that the transducer may be damaged when the boat
is dry-docked.
• Locate away from equipment which gives off heat.
• Locate away from drain pipes.
• Select a location where vibration is minimal.
T-02MSB
Sensor
cable
8 m
φ42 mm
Mounting procedure
1. Drill a hole of 21 mm in diameter in
the mounting location.
2. Pass the sensor cable through the
hole.
3. Pass gasket, washer and locknut
onto cable in that order.
4. Coat the sensor flange with high
quality sealant and then fasten the
sensor with the locknut.
(Torque: max. 59N·m)
5. Launch the boat to check for water
leakage around the sensor.
Locknut
Washer
Gasket
φ21 mm
M20
Coat with
sealant.
Holder Guide
Mounting procedure
1. Drill a hole of 25 mm in diameter in the mounting
2. Coat holder guide with high quality sealant, and
3. Set the sensor holder to the holder guide from
4. Launch the boat to check for water leakage
T-03MSB
Locknut
Washer
Gasket
φ25 mm
M24
Coat with
sealant.
φ50 mm
location.
pass gasket, washer and locknut onto holder
guide in that order and then tighten the locknut.
inside the boat and then tighten the locknut.
around the sensor.
11
1. MOUNTING
Sensor Holder
cable
8 m
Locknut
Plate thick-
ness within
25 mm

Advertisement

Table of Contents
loading