2. WIRING
Cable fabrication for the cables connected to the 03P9342 board
Signal cable RW-9600 (Between antenna unit and processor unit)
Vinyl sheath
Vinyl tape
Clamp here by cable clamp.
Other cables for optional units
Use TTYCS-1 or TTYCS-4 (Japan standard cable) or equivalent.
=
Armor
Wiring for WAGO connector
Wire
Procedures
1. Twist the conductor.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is ecure.
2-10
Armor
60
5
After exposing cores,
wind shield around the armor.
Armor
Sheath
Shield
10.1 mm
Conductor
2
S = 0.75 mm
= 1.11 mm
TTYCS-1
60: Peel paint.
After exposing cores,
Vinyl tape
wind shield around the armor.
Clamp here by cable clamp.
Press downward.
Terminal opener
WAGO connector
Twist
Shield
450
6
Coaxial cable
Coaxial cable
= 18.5
mm
Conductor
S = 0.75 mm
= 1.11 mm
TTYCS-4
Shield
L
5
6
Wiring for Coaxial cable
Clamp shied with bracket.
Tighten conductor with screw.
CAUTION
Do not use crimp-on lug to prevent
contact resistance from increasing.
5 9
14
Conductor
Fold back shield.
Armor
Sheath
Shield
2
L= Depends on equipment
connected. Measure at
the processor unit.