3.5 Transformation from one gas type to
another
The thermal module POWER MAX is supplied for operation with G20
(natural gas). However, it can be converted to operation with G30-G31
(LPG) using the dedicated accessory supplied as standard.
a
Forbidden in Belgium, Switzerland and Hungary.
b
Conversion can only be executed by Technical Assistance
Centre or staff authorised by
b
In order to execute the conversion, only follow the instructions
in this manual and the provisions of safety standards.
b
If the information contained in these instructions is not proper-
ly performed or performed by personnel not properly trained,
there is a potential risk of fuel leakage and/or carbon monoxide
production resulting in personal injury and/or injury.
b
Conversion is not complete until all the control steps described
in these instructions have been carried out.
b
After conversion, calibrate the CO2 as shown in the "Adjust-
ment" Paragraph.
Before making the transformation:
- Exclude the heat demand production or the DHW production
by lowering the related set points and the set point of the room
thermostat.
- make sure that the master switch and the thermal module's
switch are in the "Off" position
- check that the fuel interception system valve is closed.
To install the accessory:
- remove the locking screw
- pull the front panel outwards and then to the top to decouple
50
it from points A.
.
B
A
A
Versions POWER MAX 50 P DEP to POWER MAX 50 P
- disconnect the fan and gas valve electrical connections
- unscrew the swivel nut (2) on the gas pipe
- unscrew the mixer screws (6) to separate mixer-fan
- unscrew the three screws (1) to separate the valve from the fan
- insert the related diaphragm (3) onto the gasket (4) without re-
moving the gasket itself
Model
POWER MAX 50 P DEP
POWER MAX 50 P
(*)
If the CO
values indicated in the paragraph "
2
ments " are not obtained, replace the diaphragm Ø 6.5
with the diaphragm Ø 5.5.
- check the integrity of the gasket (5); replace it if necessary
- retighten the mixer screws (6)
- refit the three screws (1)
- refit the swivel nut (2)
- reconnect the fan and gas valve electrical connections
4
3
1
Versions POWER MAX 65 P to POWER MAX 80 P
- disconnect the electrical connections of the fan and the gas
valve
- unscrew the swivel nut (2) on the gas pipe
- unscrew the fan screws to separate the fan from the heat ex-
changer
- unscrew the three screws (1) to separate the valve from the fan
- insert the related diaphragm (3) onto the gasket (4) without re-
moving the gasket itself
Model
POWER MAX 65 P
POWER MAX 80 P
- check the integrity of the gasket (5); if necessary replace it
- retighten the valve
- retighten the fan screws
- screw the swivel nut (2) on the gas pipe
- reconnect the electrical connections of the fan and the gas
valve
4
3
1
int. Ø (mm)
6.5 (*)
6.5 (*)
Adjust-
5
2
6
int. Ø (mm)
6.25
6.25
5
2