Item
1
2
3
4
5
6
1.
Remove the one machine screw from the pump inlet and gently lift the bottom of the
inlet outward at a 45° angle.
2.
Gently lift the pump inlet upwards to remove. Ensure the hook on the pump inlet
clears the housing.
The particulate filter is located inside the pump inlet and the moisture filter is located
on the rear shell.
3.
Depending upon the circumstance, replace either just the particulate filter or both.
Refer to Particulate Filters and Moisture Filters in this section.
4.
Reattach the pump inlet and replace the screw. Tighten the screw using 3-4 in-lbs.
torque. Do not overtighten.
BW MaxXT II
Rear shell
Moisture filter
Pump quick connector
Pump inlet
Machine screw (1)
Particulate filter
Description
95