Honeywell BW MaxXT II User Manual page 33

1, 2, 3, and 4 gas detector
Hide thumbs Also See for BW MaxXT II:
Table of Contents

Advertisement

Note: If the Cal IR Lock option is enabled and a manual calibration is attempted, the sensor(s)
will only auto zero. Calibration will not be performed.
If enabled, the sensor(s) can only be calibrated using the IR Link with Safety Suite Device
Configurator (SSDC) or the IntelliDoX station.
If the Cal IR Lock option is enabled, the following screen displays.
To calibrate using an IR device, refer to one of the following:
See "Calibrating Using the IR Link" on page  80 for more information.
l
IntelliDoX Station User Manual
l
The detector is shipped with the CAL IR Lock option disabled.
Lockout on Self-Test Error (failed sensor lock)
If enabled and a sensor fails during startup, the following screens display and the detector
deactivates.
BW MaxXT II
32
User Manual