Table Of Commonly Used Parameters - Siruba D007S Manual

Electronic control parameter manual
Hide thumbs Also See for D007S:
Table of Contents

Advertisement

6. Table of commonly used Parameters:

Parameters Code
Actual
Display
value
value
Press P Key
01
01
02
02
03
03
05
05
07
07
08
08
09
09
40
40
41
41
45
45
46
46
Press P Key + Power ON
47
47
60
60
61
61
64
64
65
65
66
66
70
70
75
75
83
83
87
87
93
93
122
22.
※ Displaying parameter number 00.=100, 0.0=200, 0.0.=300; for example: 06.=106 parameter.
※The setting values may vary depending on the model.
Definition of Parameter
Code
Maximum sewing speed.
H
Mode of slow start
SLM
Setting of counter ratio.
CNR
V
End back-tacking speed.
Speed of slow start.
S
Stitch numbers of slow start.
SLS
Speed of automatic operation.
A
Selection of wiper function.
WON
Selection of trimmer sequence.
TM
Display of sewing speed.
SP
Rotation direction of motor.
DIR
Machine Code.
MAC
Minimum speed.
L
Speed of thread-trimming.
T
Setting of time of full output for foot-lifting
FO
solenoid.
Setting of time of duty cycle for foot-lifting
FC
solenoid.
Setting of delay time of motor operation.
FD
Cancellation of function of raising
pressure foot lifter by half-heeling
HHC
backward.
Mode selection of safety switch
SFM
Operating time of trimmer.
T2
Trimming running time selection.
L2
Operating time of wiper.
W2
Upper limit of maximum speed.
HL
12
Calibration
Unit
range
100-5000 spm
*100
A/T
---
1-9
*1
200-3000 spm
*100
100-500 spm
*10
1-9 stitches
*1
100-5000 spm
*100
ON/OF
---
ON/OF
---
0-8000 spm
*100
CC/CW
---
---
---
100-500 spm
*10
100-500 spm
*10
0-990 ms
*10
10-60%
*1
0-990 ms
*10
ON/OF
---
NC/NO
---
0-990 ms
*10
0-1500 ms
*10
0-3990 ms
*10
100-5000 spm
*100

Advertisement

Chapters

Table of Contents
loading

Table of Contents