SURFACE MOUNT USING SINE KEYS
Locating the HDL6 with keys requires the use of sine keys instead of
standard keys. Sine Keys are available in several different sizes that are
listed on our website at www.kurtworkholding.com. The keys are sold in
sets of 2 per package.
English Mounting:
The HDL6 can be properly located using (2) of the four English sine key
holes indicated by dimension QQ in Fig. 9 above. The HDL6 can be bolted
down using the four English 1/2" bolt holes indicated in Fig. 9 above by
dimension PP. The HDL6 vise can also be clamped on the sides using toe
clamps.
Metric Mounting:
The HDL6 can be properly located using the two Metric sine key holes
indicated by Dimension RR in Fig. 9 above. The HDL6 can be bolted down
using the four Metric M12 bolt holes indicated in Fig. 9 above by OO.
PROPER CHIP GUARD INSTALLATION AND USAGE
The chip guard is provided to keep chips out of the nut and screw assembly.
The center chip guard (Fig. 10-1) can be inserted so the key part
of the chip guard is inserted into the notched area of the vise bed.
Fig.10
This top chip guard will ride on top of the two side
chip guards during clamping.
The two side chip guards
(Fig. 10-2) should be placed so
that the rectangular hole in the chip
guards is placed over the rectangular peg
on the nut.
OPERATING INSTRUCTIONS