ABOUT THE PRODUCT

T his is a parts set for a sliding door system for residential
●    
& commercial use.
T he door closes in 2 soft motion steps; first slow, then
●    
fast, and opens with 1 step soft motion.
T he door can be installed without the use of tools.
●    

SPECIFICATIONS

Door height
Max.2400 mm
Door width
590 − 1200 mm
Min. Door thickness
Max. Door weight
Vertical adjustment
・ The closing speed of the soft closing type door may change depending on
the ambient temperature, operating method or installation quality.
・ Recommended ambient temperature range is 5 to 40 ℃ .
When using a light weight door, you may feel the resistance of
1
the soft closer when opening the door.

FOR YOUR SAFETY AND CORRECT INSTALLATION

Meaning of symbols
Warning
Prohibited
Caution
WARNING
If not followed, death or serious injury may result.
This product should be installed by a qualified person in accordance with this manual. If it is not installed correctly, the door
may fall and cause injury.
Provide a frame that can withstand the weight and impact of opening and closing the door. Be sure to use the specified
screws and tighten them securely. If the mounting strength is insufficient, the door may fall and cause injury.
Do not use this product for any other purpose, or with doors that are outside the specifications of this manual.
Do not disassemble or modify any parts other than those described in this document.
Caution
If not followed, injury or damage may result.
Follow the specified dimensions, specifications, and alignment of the door and frame. Warping, tilting or twisting of the
frame or door may cause failure.
If cutting any parts, make sure to remove any burrs before installation. Also check the upper track for any left-over burrs or
scraps and remove these.
This product is a part for architectural fittings. After installation, please check the function and safety of the final product.
Please inform the end user how to use the product safely.
Make sure to check the screws for slack at regular intervals (one month from first usage, half a year, and then one time
every year is recommended).
2401 − 2700 mm
700 − 1200 mm
Min. 22 mm
35 kg / door ※
1
2 mm upward, 4 mm downward
Required
Part No. FD35EVDHCMP
  
  
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FD35EV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lamp FD35EV

  • Page 1 FD35EV SLIDING DOOR SYSTEM Installation Manual (For Mortised, Drop or False Ceiling, with Surface Mount Rollers- with Dual Soft Close) Part No. FD35EVDHCMP Thank you for using our product. Before installation, please read this manual thoroughly to ensure correct installation. Please keep this manual at hand for future reference.
  • Page 2 Trigger Jig (surface mount) (recessed mount) (surface mount) (recessed mount) FD35EV-TRG Item No. FD35EV-TRM-SC FD35EV-TRH-SC FD35EV-TRM FD35EV-TRH FD35EV-WRM-DSC FD35EV-WRM-SP8 FD35EV-TRJ Trigger Trigger Trigger Item Hole pitch :300 mm Hole pitch    : 300 mm...
  • Page 3 Caution If the position is wrong, pull back the trigger catcher to the correct position using a 6 mm diameter round bar. Trigger catcher (Red colored part) Correct set position Correct set position Trigger catcher (Red colored part) Incorrect set position 4...
  • Page 4 Fastening of Additional Trigger Fasten trigger to the hole made during procedure with provided screws. The jig makes it easy to install the trigger. Assemble trigger to jig.      A lign trigger with the      T urn the jig 90゚ and fix   ...
  • Page 5 Adjustment of Door Height Caution Do not turn the adjustment screw beyond the adjustment range. It may cause damage Adjustment range :6 mm 2 mm 4 mm Hanging bolt root Adjust by turning the hanger bolt of the Down upper roller with spanner wrench . Adjusting, Fastening the Floor Guide If the door movement is not smooth, remove the door, Tighten all four screws after the adjustment.
  • Page 6 Appendix  1 How to remove door Use a 10 mm support under the door. Caution ❶Plug in Pay attention not to let the door fall. ❸Pull out Insert the flat end of the spanner into ❷Push up the lever part of the upper roller. blade screwdriver can be used as a substitute.
  • Page 7 Appendix  4 Trigger positions 187.5 Door width−361 Standard installation Upper track installed inside door jamb Crimped trigger Available opening width Door width Leading edge when the door Reference line for leading edge is fully opened (Leading edge when the door is 187.5 closed) Reference line for trailing edge...
  • Page 8 SUGATSUNE AMERICA, INC          Tokyo, JAPAN Shanghai, CHINA California, USA Phone: +81 (0)3 3866 2260 E-mail:export@sugatsune.co.jp Phone: +86 21 3632 1858  E-mail:lamp@sugatsune.com.cn Phone: +1 310 329 6373 E-mail:sales@sugatsune.com SUGATSUNE KOGYO (UK) LTD Guangzhou, CHINA Chicago, USA          Reading, UK Phone: +86 20 6639 3552  E-mail:lamp@sugatsune.com.cn...

Table of Contents