3.0 installation planning

WEAR PROTECTIVE GLOVES, SAFETY GLASSES, AND BOOTS/SHOES.
CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS
NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF
COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE
DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES
ARE HAZARDOUS. DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN
FROM ATTIC SPACES, BASEMENTS OR ABOVE THE ROOFING WHERE OTHER HEATING APPLIANCES
OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR. THESE PRECAUTIONS WILL REDUCE THE
POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL. THE OUTSIDE AIR INLET MUST
REMAIN CLEAR OF LEAVES, DEBRIS ICE AND/OR SNOW. IT MUST BE UNRESTRICTED WHILE
APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE
AND AN INABILITY TO MAINTAIN A FIRE. SMOKE SPILLAGE CAN ALSO SET OFF SMOKE ALARMS.
NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE APPLIANCE MUST NOT BE
INSTALLED AGAINST VAPOUR BARRIERS OR EXPOSED INSULATION. LOCALIZED OVERHEATING
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT
TO PREVENT PERSONAL INJURY KEEP HAND TOOLS IN GOOD CONDITION, SHARPEN CUTTING
ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO THE ENCLOSURE TO PREVENT FIRES.
DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (2.1M) (CEILING OF
ENCLOSURE TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT).
The appliance is shipped with a set-up face that is 1/8" (38m) larger on the top,
bottom and each side than the faceplate. Leave the set-up face in place to act as a
template when installing the finishing face.
IMPORTANT
This appliance, fully dressed, weighs 850 lbs (386kg). Ensure there is adequate
floor support for the appliance, chimney and facing material. Some material could
weigh thousands of pounds.
3.1

location and clearances

We recommend that the appliance be secured to the floor in
all cases.
Using the door opening as a datum, level the appliance by
shimming underneath the appliance. Remove and discard the
lifting handles. Bend the tabs down and secure the appliance to
the floor.
BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
COULD OCCUR AND A FIRE COULD RESULT.
AIR, GRILLE OR LOUVRE OPENINGS. DO NOT ADD A HOOD.
EDGES AND MAKE SURE TOOL HANDLES ARE SECURE.
WARNING
!
9
68.3D
W415-1501 / C / 10.11.17