This wood appliance needs periodic inspection and repair. It is against United States federal regulations to operate this wood
appliance in a manner inconsistent with the operating instructions in this manual.
SAFETY INFORMATION
WARNING
!
If the information in these instructions is not followed exactly, a fi re
or explosion may result causing property damage, personal injury or
death. Please read the entire manual before you install and use your
appliance. This appliance has been tested for use with gas log sets.
Follow the instructions in the installation manual for proper use.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed
too close can catch fi re.
- Children and pets must be kept from touching the appliance when
it is hot.
- The chimney must be sound and free of cracks. Before installing
this appliance, contact the local building or fi re authority and follow
their guidelines.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- This appliance is designed to burn natural wood only. Higher
effi ciencies and lower emissions generally result when burning air
dried seasoned hardwoods, as compared to softwoods or to green
or freshly cut hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine
oil, etc.
- Do not burn trash or garbage, lawn clippings/waste, rubber,
waste petroleum products, paints or paint thinners/solvents, plastic,
materials containing asbestos, construction debris, railroad ties or
treated wood, manure or animal remains, salt water driftwood or
salted materials, unseasoned wood, coal, charcoal, coloured paper,
cardboard, plywood or particleboard. Burning these materials may
result in release of toxic fumes or render the appliance ineffective and
cause smoke.
- Do not let the appliance become hot enough for any part to glow
red.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
ADD MANUAL TITLE
INSTALLATION MANUAL
LABORATORIES, INC. AS PER THE STANDARDS : ULC S610, UL 127 U.S. THE
Project Number:
CSA / OMNI
0415WF013S
0415WF0313E
/ INTERTEK
LOGO
HIGH COUNTRY™ NZ5000
PRODUCT NAME™
ADD PRODUCT IMAGE
THIS APPLIANCE HAS BEEN SAFETY TESTED AND LISTED BY OMNI TEST
NZ5000 IS AN EPA LOW MASS WOOD-BURNING FIREPLACE VOLUNTARY
PROGRAM PHASE 2 EMISSION LEVEL QUALIFIED MODEL.
ENGLISH
FRENCH PG. 41
ADD ____ ILLUSTRATED
FOR INDOOR USE ONLY
W415-1720 / 08.21.17

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon HIGH COUNTRY NZ5000

  • Page 1 CSA / OMNI 0415WF013S 0415WF0313E / INTERTEK LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com W415-1720 / 08.21.17 $10.00...
  • Page 2 safety information WARNING WARNING • This appliance is hot when operated and can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 safety information WARNING • Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc. • Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to smoke spillage in your home. •...
  • Page 4: Table Of Contents

    table of contents dimensions general information general instructions features this cordwood fuel fi replace packing list rating plate information hardware list installation planning location and clearances ventilation openings outside combustion air fl oor protection / ember strip and hearth extensions hearth examples fl...
  • Page 5: Dimensions

    1.0 dimensions dimensions FRONT VIEW RIGHT SIDE VIEW TOP VIEW 11" 280mm 10 1/8" 73 3/8" 257mm 1864mm 65 3/16" 1656mm 9 3/4" 247mm 26 5/8” 676mm 1 1/16" GAS INLET* 27mm 36 5/8" 931mm 5 11/16" 41 15/16" 144mm 1065mm 15 5/8"...
  • Page 6: General Information

    general information 2.0 general information general instructions WARNING • Before installing this appliance, contact the local building or fi re authority and follow their guidelines. • This appliance must be installed by a qualifi ed installer. Follow the installation directions. Do not operate without fully assembling all components.
  • Page 7: Features

    general information features • Depending on the loading method and size of log, maximum length of 18” (45.7cm). • Large glass door for maximum visibility. • Fully refractory lined fi rebox. • Closable outside combustion air damper. • Closable fl ue damper. •...
  • Page 8: Rating Plate Information

    2 des émissions États Unis EPA à bois. Pour minimiser la fumée, toujours fonctionner votre foyer conformément aux instructions du fabricant figurant dans le manuel du propriétaire. Des renseignements supplémentaires sur le programme de l'EPA est disponible à www.epa.gov/burnwise/index.html NZ5000 W385-2174 24 NAPOLEON ROAD. BARRIE, ONTRAIO L4M 0G8 CANADA W415-1720 / 08.21.17...
  • Page 9: Hardware List

    general information hardware list Reference Part # Description Quantity W570-0176 #10-24 x 1/2” Machine Screw W615-0159 Door Levelling Shim W570-0058 1/4”-20 x 5/8” Machine Screw W415-1720 / 08.21.17...
  • Page 10: Installation Planning

    installation planning 3.0 installation planning WARNING • Wear gloves, protective footwear and safety glasses for protection. • Carefully follow the instructions for assembly of the pipe and other parts needed to install the appliance. Failure to do so may result in a fi re, especially if combustibles are too close to the appliance or chimney and air spacers are blocked, preventing the free movement of cooling air.
  • Page 11: Ventilation Openings

    installation planning ventilation openings It is recommended to provide air circulation within the enclosure by installing ventilation grilles (minimum openings of 40 sq. inches (0.03 sq. meters) at both fl oor and ceiling levels of the enclosure. These grilles must not restrict the fl...
  • Page 12: Fl Oor Protection / Ember Strip And Hearth Extensions

    installation planning fl oor protection / ember strip and hearth extensions WARNING • Hearth extensions are to be installed only as described to prevent high temperatures from occurring on concealed combustible materials. Hearth ember strips prevent burning or hot particles from inadvertently falling directly on combustible surfaces in the event the building should settle and disturb the original construction.
  • Page 13: Hearth Examples

    installation planning hearth examples FLUSH HEARTH MIN. 1/4” (6.4mm) TILE OR MARBLE 20” MIN. (50.8cm) COMBUSTIBLE FLOOR EMBER STRIP MIN. 1” (25mm) CEMENT BOARD RAISED HEARTH 20” MIN. (50.8cm) ” (125mm) COMBUSTIBLE FLOOR NON-COMBUSTIBLE MATERIALS EMBER STRIP SUCH AS CEMENT BLOCKS OR BRICKS RAISED APPLIANCE MIN.
  • Page 14: Fl Ue Damper Operation

    installation planning fl ue damper operation OPEN CLOSED OPEN OPEN CLOSED To close the fl ue damper, pull the damper control rod down and push it to the right. To open the damper, pull down slightly and push the damper con- trol rod to the left side and release.
  • Page 15: Installation

    installation 4.0 installation WARNING • Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this single wall pipe may radiate suffi cient heat to combustible chase materials to cause a fi re. •...
  • Page 16: Typical Chimney Installation

    installation typical chimney installation RAIN CAP RAIN CAP RAIN CAP STORM COLLAR STORM COLLAR STORM COLLAR ROOF FLASHING ROOF FLASHING ROOF FLASHING 15 FT ATTIC INSULATION ATTIC INSULATION ATTIC INSULATION (4.6m) SHIELD SHIELD SHIELD MINIMUM 34 FT (10.4m) 15 FT 15 FT MAXIMUM (4.6m)
  • Page 17: Adding Chimney Sections

    installation adding chimney sections Add chimney sections, according to the manufacturers installation instructions. If the chimney system passes through an attic space a rafter radiation shield or attic insulation shield is required. The chimney must extend at least 3ft (0.9m) above its point of contact with the roof and at least 2ft (0.6m) higher than any wall, roof or building within 10ft (3.1m).
  • Page 18: Offset Chimney Installation

    installation offset chimney installation WARNING Chimney sections installed between an offset and return require structural support to reduce off-center loading and to prevent chimney sections from separating at the chimney joists. The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA. Do not combine offset chimney components to exceed these angles.
  • Page 19: Installing Fl Ashing And Storm Collar

    installation installing fl ashing and storm collar The following are generic installation instructions for installing the flashing around a chimney. Installation of all types of factory-built chimney systems is to be in accordance with the chimney manufacturer’s installation instructions. Remove the nails from the shingles above and to the sides of the chimney. Place the flashing over the chimney pipe and slide underneath the sides and upper edge of the shingles.
  • Page 20: Use With Gas Log Sets

    installation use with gas log sets WARNING • It is mandatory that the fl ue damper is set open for use with vented type gas long sets. • Only unvented gas log sets which have been found to comply with the standard for unvented room heaters, ANSI/IAS/AGA Z21.11.2, are to be installed with this appliance.
  • Page 21: Framing

    framing 5.0 framing WARNING • In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the appliance body, it is recommended that the walls of the appliance enclosure be “fi nished” (i.e.: drywall/sheetrock), as you would fi...
  • Page 22: Fi Nishing Material

    framing fi nishing material WARNING • Screws used to fasten fi nishing materials to the face of the appliance above the guillotine screen and door must not penetrate more than 1/2” (13mm) into the sheet metal front panels. Refer to the “dimensions” section for specifi...
  • Page 23: Minimum Clearance To Combustibles

    framing minimum clearance to combustibles Framed enclosure Rear - 0” (0mm) to stand-offs Sides of the appliance - 6” (15.2cm) from the side of the appliance Enclosure ceiling - 84” (213.4cm) from the base of the appliance Ceiling in front of appliance - 84”...
  • Page 24: Minimum Mantel Clearances

    framing minimum mantel clearances WARNING • Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel, front, etc.) are clearly maintained.
  • Page 25: Finishing (See "Finishing Material" Section)

    fi nishing 6.0 fi nishing (see “fi nishing material” section) WARNING • Use only a non-combustible material to fi nish the face of the appliance. A non-combustible material such as cement board is required for this purpose. • Ventilation openings are recommended for all enclosures. •...
  • Page 26: Door Level Adjustment

    fi nishing door level adjustment WARNING • Do not use substitute materials. • Glass may be hot; do not touch glass until cooled. Door adjustment may be necessary if door is not level. note: Door adjustment is strictly trial and error; you may need to perform this adjustment a few times until the desired door angle is attained.
  • Page 27 fi nishing Close door. Locate the two hex screws on the left side If the left side of the door is not resting on the hearth of the door that secures the bearing assembly. when the door is fully closed, signifi cantly loosen (but do Do not loosen the bearing bolts.
  • Page 28 fi nishing note: For clarity purposes, some parts of the appliance have been hidden. Tighten loosened hex screw and verify the door is level. It may be necessary to add or remove an Insert shims in behind the bearing bracket until the gap additional shim to achieve optimal results.
  • Page 29: Balance Weight Adjustment

    fi nishing counter weight adjustment Counter weights have been installed and supplied in this appliance to ensure your screen and glass door move- ment is balanced and operates smoothly. If the glass or screen door become unbalanced (falling or rising rapidly), it is important to add or subtract the counter weight to the doors to ensure they perform properly.
  • Page 30: Fi Rebrick Installation

    fi nishing fi rebrick installation WARNING • Operation of the appliance without the fi rebricks can result in excessive temperatures that will damage the appliance, chimney and the surrounding enclosure. note: Ensure fi bre panels set in behind brick are in good condition before installing fi rebrick. If fi bre panels need to be replaced, hold panels in position or secure with masking tape until fi...
  • Page 31: Baffl E Installation

    fi nishing baffl e installation Your appliance is equipped with two baffl es. For protection, the rear baffl e is shipped inside your appliance box and the front baffl e is shipped laying on the fi rebox base inside your appliance. For proper appliance operation and installation, the rear baffl...
  • Page 32: Smoke Chamber Insulation Panel Installation

    fi nishing smoke chamber insulation panel installation note: For clarity purposes, some parts of the appliance have been hidden. 1. Slide front baffl e (1) up and out of retaining 2. Remove 2 screws from both brackets then slide bracket and pivot straight down and out of lower right side panel (1) out.
  • Page 33: Door Glass Replacement

    fi nishing door glass replacement WARNING • Do not use substitute materials. • Glass may be hot; do not touch glass until cooled. • Care must be taken when removing and disposing of any broken door glass or damaged components. Be sure to vacuum up any broken glass from inside the appliance before operation.
  • Page 34: Screen Replacement

    screen replacement WARNING • Risk of Injury! • Perform only when appliance is cool • Clean fi rebox of all embers and ash • Remove andirons 1. Removing the screen will result in the screen immediately rising, use caution. It is recommended to have another person assist in holding the screen door while the screen frame is being removed.
  • Page 35: 7.0 Replacements

    7.0 replacements W415-1720 / 08.21.17...
  • Page 36 replacements W415-1720 / 08.21.17...
  • Page 37: 8.0 Troubleshooting

    8.0 troubleshooting symptom problem test solution Smoke enters the room Damper in closed Open damper. during start-up position. See “operation” section. Cold air blockage in Burn a piece of newspaper to establish a draft. chimney. Negative pressure in Open outside air control damper. building.
  • Page 38: Notes

    notes 9.0 notes W415-1720 / 08.21.17...
  • Page 39 notes 29.1 W415-1720 / 08.21.17...
  • Page 40 NAPOLEON CELEBRATING OVER 40 YEARS OF HOME COMFORT PRODUCTS 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686...
  • Page 41 CSA / OMNI Numéro de Projet: / INTERTEK 0415WF013S 0415WF0313E LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1 (866) 820-8686 • www.napoleonfoyers.com • hearth@napoleonproducts.com $10.00 W415-1720 / 08.21.17...
  • Page 42 consignes de sécurité AVERTISSEMENT AVERTISSEMENT • Cet appareil est chaud lorsqu’il fonctionne et peut causer de graves brûlures en cas de contact. • Toute modifi cation apportée à cet appareil LA VITRE CHAUDE CAUSERA ou aux contrôles peut être dangereux et est DES BRÛLURES.
  • Page 43 consignes de sécurité AVERTISSEMENT • Seulement les portes/façades certifi ées pour cet appareil peuvent être utilisées avec cet appareil. • Gardez les matériaux d’emballage hors de la portée des enfants et mettez ces matériaux au rebut de façon sécuritaire. Comme tous les emballages de plastique, ces matériaux ne sont pas des jouets et doivent demeurer hors de la portée des enfants et des bébés.
  • Page 44: Http://Mynapoleon.napoleonproducts.com/Download/Index/44/1

    table des matières dimensions information générale instructions générale caractéristiques spécifi cations de chauffage liste des articles information sur la plaque d’homologation hardware list planification de l’installation dégagement et placement ouvertures de ventilation air comburant extéreiur pare-braises et base de protection examples de bases de protection opération de registre installation...
  • Page 45: Dimensions

    1.0 dimensions dimensions VUE FRONTALE VUE DU CÔTÉ DROITE VUE DE DESSUS 11" 280mm 10 1/8" 73 3/8" 257mm 1864mm 65 3/16" 1656mm 9 3/4" 247mm 26 5/8” 676mm 1 1/16" GAS INLET* 27mm 36 5/8" 931mm 5 11/16" 41 15/16" 144mm 1065mm 15 5/8"...
  • Page 46: Information Générale

    information générale 2.0 information générale instructions générale AVERTISSEMENT • Avant d’installer cet appareil, contactez les autorités locale du bâtiment ou le service des incendies et suivez leurs directives. • Cet appareil doit être installé par un installateur qualifi é. Suivez les instructions d’installation. Ne pas utiliser sans installer tous les composants.
  • Page 47: Caractéristiques

    information générale caractéristiques • Selon la méthode de chargement et la taille des bûches, la longueur maximale des bûches est de 18 po (45.7 cm). • Grande portes vitrées pour un maximum de visibilité. • Revêtement de briques réfractaires qui protège la chambre de combustion. •...
  • Page 48: Information Sur La Plaque D'homologation

    2 des émissions États Unis EPA à bois. Pour minimiser la fumée, toujours fonctionner votre foyer conformément aux instructions du fabricant figurant dans le manuel du propriétaire. Des renseignements supplémentaires sur le programme de l'EPA est disponible à www.epa.gov/burnwise/index.html NZ5000 W385-2174 24 NAPOLEON ROAD. BARRIE, ONTRAIO L4M 0G8 CANADA W415-1720 / 08.21.17...
  • Page 49: Hardware List

    information générale hardware list Référence No. de pièce Description Quantité W570-0176 #10-24 x 1/2” Vis à métaux Cale de nivellement de la porte W615-0159 W570-0058 1/4” - 20 x 5/8” Vis à métaux W415-1720 / 08.21.17...
  • Page 50: Dégagement Et Placement

    planifi cation de l'installation 3.0 planifi cation de l’installation AVERTISSEMENT • Portez des gants et des lunettes de protection. • Suivez attentivement les instructions pour l’assemblage de la cheminée et des autres composants nécessaires à l’installation de l’appareil. Toute omission pourrait causer un incendie, particulièrement si des matériaux combustibles sont trop près de l’appareil ou de la cheminée eet que des ouvertures d’air sont bloquées, empêchant la libre circulation de l’air de refroidissement.
  • Page 51: Planification De L'installation

    planifi cation de l'installation ouvertures de ventilation Il est recommandé d’installez une grille d’aération (ouvertures minimales de 40 pouces carrés [0,03 mètres carrés) au niveau de plancher et une autre au niveau du plafond de l’enceinte. Ces grilles ne peut pas restreindre la circulation de la chaleur de plus de 25%.
  • Page 52: Pare-Braises Et Base De Protection

    planifi cation de l'installation pare-braises et base de protection AVERTISSEMENT • Les bases de protection doivent être installées uniquement comme décrit, afi n dempêcher les matériaux combustibles dissimulés d’être exposés à de hautes températures. Les pare-braises empêchent toute particule chaude ou en combustion de tomber de façon accidentelle directement sur des surfaces combustibles, dans l’éventualité...
  • Page 53: Examples De Bases De Protection

    planifi cation de l'installation examples de bases de protection BASE À ÉGALITÉ MIN. 1/4” (6.4mm) TUILE OU MARBRE MIN. 1/4” (6,4mm) TILE OR MARBLE 20” MIN. (50.8cm) COMBUSTIBLE FLOOR PLANCHER COMBUSTIBLE EMBER STRIP PARE-BRAISES MIN. 1” (25mm) CEMENT BOARD PANNEAU DE CIMENT MIN. 1” (25mm) BASE SURÉLEVÉE 20”...
  • Page 54: Opération De Registre

    planifi cation de l'installation opération de registre OPEN CLOSED OUVRIR OPEN OPEN CLOSED FERMÉ Pour fermer le registre, tirez sur le levier de commande du registre et poussez-le vers la droite. Pour ouvrir le registre, tirez sur le levier de commande du registre légèrement vers le bas et poussez-le vers la gauche, puis relâchez-le.
  • Page 55: Installation

    installation 4.0 installation AVERTISSEMENT • Ne jamais installer un conduit de raccordement à paroi simple ou un tuyau de poêle dans une structure d’enceinte. Les températures plus élevées de ce conduit à paroi simple peuvent irradier suffi samment de chaleur aux matériaux combustibles de l’enceinte pour causer un incendie. •...
  • Page 56: Installation Typique De La Cheminée

    installation installation typique de la cheminée CHAPEAU CHAPEAU CHAPEAU COLLET DE SOLIN COLLET DE SOLIN COLLET DE SOLIN SOLIN DE TOIT SOLIN DE TOIT SOLIN DE TOIT ÉCRAN DE ÉCRAN DE ÉCRAN DE PROTECTION PROTECTION PROTECTION 15 PI POUR GRENIER POUR GRENIER POUR GRENIER (4,6m)
  • Page 57: Ajout De Sections De Cheminée

    installation ajout de sections de cheminée Ajoutez des sections de cheminée, selon les instructions d’installation des manufacturiers. Si la cheminée devra dépasser par l’espace grenier une écran protecteur de chevrons ou une bouclier d'isolation du grenier est requis. La cheminée doit dépasser le toit d’au moins 3’ (0,9m) de son point de contact avec la toiture, et 2’...
  • Page 58: Installation De La Cheminée Avec Déviation

    installation installation de la cheminée avec déviation AVERTISSEMENT Les conduits de raccordement installés entre une déviation et un coude de retour requièrent un support afin de réduire la charge excentrée et prévenir toute séparation entre les sections de conduit aux joints. La cheminée ne devrait pas être construite avec un angle de déviation excédant 45°...
  • Page 59: Installation Du Solin Et Du Collet De Solin

    installation installation du solin et du collet de solin Les instructions d’installation suivants sont générales pour l’installation du solin autours du chiminée. l’Installation de tous les types de systèmes construits en usine doivent être installées en confomé avec les instructions d’installation du fabricant de la cheminée.
  • Page 60: Utilisation Avec Les Ensembles De Bûches À Gaz

    installation utilisation avec les ensembles de bûches à gaz WARNING • Il est obligatoire que le registre de tirage soit tenu ouvert pour une utilisation avec les ensembles de bûches à gaz ventilés. • euls les ensembles de bûches à gaz non ventilés qui s’avèrent conformes à la norme pour les appareils de chauffage non ventilés, ANSI/IA S/AGA Z21.11.2, peuvent être installés avec cet appareil.
  • Page 61: Ossature

    ossature 5.0 ossature AVERTISSEMENT • Afi n d’éviter la possibilité que de l’isolant ou un coupe-vapeur n’entrent en contact avec l’extérieur du caisson, il est conseillé d’installer l’appareil contre des murs « fi nis » (c.-à.-d. panneau de gypse), comme tout autre mur de la maison.
  • Page 62: Matériaux De Fi Nition

    ossature matériaux de fi nition AVERTISSEMENT • Les vis utilisées pour fi xerr les matériaux de fi nition à la face de l’appareil au-dessus de l’écran de la guil- lotine et la porte ne doivent pas dépasser 1/2” (13mm) dans les panneaux frontale de tôle. Référez à la section «...
  • Page 63: Dégagements Minimaux Aux Matériaux Combustibles

    ossature dégagements minimaux aux matériaux combustibles Ossature de l’appareil Arrière - 0” (0mm) aux espaceurs Côtés de l’appareil - 6” (15.2cm) du côté de l’appareil Plafond de l’enceinte - 84” (213.4cm) du base de l’appareil Plafond en avant de l’appareil - 84”...
  • Page 64: Dégagements Minimaux De La Tablette

    ossature dégagements minimaux de la tablette AVERTISSEMENT • Risque d’incendie. Conservez tous les dégagements aux matériaux combustibles spécifi és. Ne pas respecter ces instructions peut causer un incendie ou une surchauffe. Assurez-vous que tous les dégagements (arrière, côtés, dessus, évents, tablette, façade, etc.) sont respectés à la lettre. •...
  • Page 65: Finitions

    fi nitions 6.0 fi nitions AVERTISSEMENT • Utilisez uniquement un matériau incombustible pour la fi nition de la façade de l’appareil. Un matériau in- combustible tel un panneau de ciment est requis à cette fi n. • Des ouvertures de ventilation sont requises pour toutes les enceintes. •...
  • Page 66: Réglage Du Niveau De La Porte

    fi nitions réglage du niveau de la porte AVERTISSEMENT • N’utilisez pas de matériaux de substitution. • La vitre peut être chaude, ne touchez pas le vitre jusqu’à ce qu’elle ait refroidi. Réglage de la porte peut être nécessaire si la porte n’est pas d’aplomb.
  • Page 67 fi nitions Fermez la porte. Repérez les six vis hexagonales sur le Si le côté gauche de la porte n’est pas appuyé sur le côté gauche de la porte qui maintiennent l’ensemble de foyer quand la porte est fermée, desserrez fortement la charnière.
  • Page 68 fi nitions remarque: Par souci de clarté, certaines pièces de l’appareil ont été masquées. Serrez la vis hexagonale desserrée et assurez-vous que la porte est d’aplomb.Vous pourriez devoir ajouter Insérez des cales derrière le support de la charnière ou enlever une cale pour obtenir un résultat optimal. jusqu’à...
  • Page 69: Réglage Des Masses D'équilibrage

    fi nitions réglage des masses d’équilibrage Masses d’équilibrage ont été ajoutées à cet appareil pour aller à l’encontre du poids de la guillotine à l’arrière de l’appareil, Ils stabilisent l’équilibre entre le mouvement de la porte et de l’écran. Si la porte vitrée ou la porte d’écran deviennent déséquilibrée (tombe ou augmente rapidement), il est important d’ajuster les masses d’équilibrage des portes pour assurer qu’ils effectuent correctement.
  • Page 70: Installation De La Brique Réfractaire Et Opération Amortisseur

    fi nitions installation de la brique réfractaire et opération amortisseur AVERTISSEMENT • L’utilisation de l’appareil sans les défl ecteurs peut causer des températures excessive qui peuvent endommager l’appareil, la cheminée et l’enceinte. installation de la brique réfractaire remarque: Assurez-vous que les panneaux en fi bre installés derrière la brique sont en bon état avant d’installer la brique réfractaire.
  • Page 71: Installation Des Défl Ecteurs

    fi nitions installation des défl ecteurs Votre appareil est équipé de deux défl ecteurs. À titre de protection, le défl ecteur arrière est livré dans la boîte de l’appareil, alors que le défl ecteur avant est livré déposé sur la base du foyer à l’intérieur de l’appareil. Pour que l’appareil soit installé...
  • Page 72: Installation Des Panneaux D'isolation De La Chambre À Fumée

    fi nitions installation des panneaux d’isolation de la chambre à fumée remarque: Par souci de clarté, certaines pièces de l’appareil ont été masquées. 1. Faites glisser le défl ecteur avant (1) vers le haut 2. Enlevez les deux vis des supports avant, puis pour le sortir du support et inclinez-le vers sortez le panneau latéral droit inférieur (1).
  • Page 73: Remplacement De Verre Porte

    fi nitions remplacement de verre porte AVERTISSEMENT • N’utilisez pas de matériaux de substiturion. • La vitre peut être chaude, ne touchez pas la vitre jusqu’à ce qu’elle ait refroidi. Utilisez de prudence lorsque vous enlevez et jetez des débris de verrie ou des composants endommagés. •...
  • Page 74: Replacement De L'écran

    fi nitions replacement de l’écran AVERTISSEMENT • Risque de blessure! • N’effectuez le remplacement qu’une fois l’appareil refroidi. • Retirez toutes les braises et cendres du foyer. • Retirez les bornes de chenet. Lorsque vous retirerez l’écran, celui-ci se soulèvera immédiatement; soyez prudent. Il est recommandé...
  • Page 75: Rechanges

    7.0 rechanges fi nitions W415-1720 / 08.21.17...
  • Page 76 rechanges fi nitions W415-1720 / 08.21.17...
  • Page 77: 8.0 Guide De Dépannage

    8.0 guide de dépannage fi nitions SYMPTÔME PROBLÈME SOLUTIONS De la fumée se répand Fermé registre d’air Registre d’air ouvert dans la pièce durant Blocage d’air froid dans la Brûlez un morceau de papier journal pour créer un l’allumage. cheminée. tirage.
  • Page 78: Notes

    fi nitions 9.0 notes W415-1720 / 08.21.17...
  • Page 79 notes...
  • Page 80 É À À À ODUITS DE CONFORT 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Téléphone: 1-866-820-8686 napoleonproducts.com...

Table of Contents