INSTALLATION MANUAL
R-KEY-MBUS
Converter of M-BUS to ModBUS RTU/TCP-IP protocol
EN
DOCUMENTATION
SENECA s.r.l.
Via Austria, 26 – 35127 – PADOVA – ITALY
Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287
For manuals in other languages and the configuration software,visit:
www.seneca.it/products/r-key-mbus
MI00563-0-EN
1/6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R-KEY-MBUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seneca R-KEY-MBUS

  • Page 1 INSTALLATION MANUAL R-KEY-MBUS Converter of M-BUS to ModBUS RTU/TCP-IP protocol DOCUMENTATION SENECA s.r.l. Via Austria, 26 – 35127 – PADOVA – ITALY Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287 For manuals in other languages and the configuration software,visit: www.seneca.it/products/r-key-mbus MI00563-0-EN...
  • Page 2: Module Layout

    MODULE LAYOUT 32.2 mm 53.3 mm Dimensions (LxHxD) 53.3 x 90 x 32.2 Weight 80 g Case Self-extinguishing UL94-V0 PC / ABS material SIGNALS VIA LED ON FRONT PANEL STATUS LED meaning Powered MeterBus interface M-BUS PWR NON powered MeterBus interface SERIAL Rx Flashing Data reception on RS485 or RS232 port...
  • Page 3: Technical Specifications

    TECHNICAL SPECIFICATIONS EN61000-6-4 Electromagnetic emissions, industrial environment. STANDARDS EN61000-6-2 Electromagnetic immunity, industrial environment. EN60950-1 Safety. POWER SUPPLY Voltage: 11 – 40 Vdc, 19 - 28 Vac, 50 - 60 Hz; Absorption: Max p.: 3.8 W. Ethernet MeterBUS RS485/RS232 INSULATION POWER 500 Vdc SUPPLY 1500 Vdc...
  • Page 4: Web Server

    N.B.: through the software for the SDD (SENECA Discovery Device) Windows PC, downloadable for free from the www.seneca.it/prodotti/sdd site, it is possible to easily identify the device on the network and view / change the IP address in a few steps (see USER manual for details).
  • Page 5: Electrical Connections

    For the connection it is possible to use a two-wire shielded telephone cable or an unshielded duplex cable following the indications in the table. If a shielded cable is used, this must be connected to earth only from the R-KEY-MBUS side.
  • Page 6: Wall Mounting

    Product information sales@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes.