Configure Bmc Management Address On Bmc Console; Run The Unified Firmware Updater Tool From A Linux Server - Dell EMC VEP4600 Installation Manual

Hide thumbs Also See for EMC VEP4600:
Table of Contents

Advertisement

Configure BMC management address on BMC console

From the BMC console, run the following commands:
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 ipsrc <static or dhcp>
NOTE:
If using static addressing, follow the next 3 commands:
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 ipaddr xxx.xx.xxx.xx
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 netmask 255.255.255.0
ipmitool -H 127.0.0.1 -U admin -P admin lan set 1 defgw ipaddr xxx.xx.xxx.254
Run the Unified firmware updater tool from a Linux
server
1. Deploy a Linux OS (CentOS, RedHat, Ubuntu) that connects to the VEP4600 BMC network. Can be a VM based Linux
server.
2. Verify you can reach the BMC ip address with ipmitool:
test_user@ubs18-04:~$ sudo bash
[sudo] password for test_user:
root@ubs18-04:~# ipmitool -I lanplus -H xxx.xx.xx.xxx -U admin -P admin power status
Chassis Power is on
3. Run the UFW from the Linux (CentOS, RedHat, Ubuntu) server with the following command:
./vep4600_ufw_x.x <BMC IP address> interactive
root@ubs18-04:~# cd Downloads/
root@ubs18-04:~/Downloads# ls -l
total 186916
-rw-rw-r-- 1 test_user test_user 98093308 Aug 17 15:43 vep4600_ufw_3.3
root@ubs18-04:~/Downloads# chmod u+x vep4600_ufw_3.3
root@ubs18-04:~/Downloads# ls -l
total 186916
-rwxrw-r-- 1 test_user test_user 98093308 Aug 17 15:43 vep4600_ufw_3.3
root@ubs18-04:~/Downloads# ./vep4600_ufw_3.3 xxx.xx.xx.xxx interactive
Creating directory temp
Verifying archive integrity...
Uncompressing release
firmware_updater/
firmware_updater/x710/
firmware_updater/x710/spsetup.sh
firmware_updater/x710/DX69G.txt
firmware_updater/x710/BootIMG.FLB
firmware_updater/x710/6VDPG.txt
firmware_updater/x710/demere_map.txt
firmware_updater/x710/68M95.txt
firmware_updater/x710/nut_msg.txt
firmware_updater/x710/nvminv.cfg
firmware_updater/x710/98-secupdusb.rules
firmware_updater/x710/harbor_map.txt
firmware_updater/x710/shellfit.sh
firmware_updater/x710/XD56X.txt
firmware_updater/x710/getSystemId
firmware_updater/x710/OSFlavourUtils.sh
firmware_updater/x710/os_mapping.xml
firmware_updater/x710/svmExeMsg.xsl
firmware_updater/x710/PIEInfo.txt
18
Upgrade firmware through BMC
100%
MD5 checksums are OK. All good.